Horário de atendimento: Segunda a sexta, das 9h às 18h.
1SAM360200R1011 - 1SAM360200R1011 ABB MO132-16B Magnetic only motor guard
Em estoque Produto em alta

1SAM360200R1011

1SAM360200R1011 ABB MO132-16B Magnetic only motor guard

$0.00 USD
4514 em estoque
Especificações principais
: 1SAM300507F0003
ETIM 5: EC000074 - Motor protective circuit-breaker
ETIM 6: EC000074 - Motor protection circuit-breaker
ETIM 7: EC000074 - Motor protection circuit-breaker
Informações do fornecedor
ABB
ABB
Produtos: 44170
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
1SAM300507F0003
ETIM 5 EC000074 - Motor protective circuit-breaker
ETIM 6 EC000074 - Motor protection circuit-breaker
ETIM 7 EC000074 - Motor protection circuit-breaker
ETIM 8 EC000074 - Motor protection circuit-breaker
UNSPSC 39121521
eClass V11.0 : 27370401
Remarks For overload protection of the motors, an appropriate thermal or electronic overload relays must be used
Standards IEC 60077-1 (applicable parts)
Power Loss at Rated Operating Conditions per Pole 1.9 W
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Actuator Type Rotary Handle
Setting Range None
Terminal Type Screw Terminals
WEEE Category 5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate 1SAA963002-2002
UL Certificate E137861-20090225
WEEE B2C / B2B Business To Business
CCC Certificate 2020980307003526
CQC Certificate CQC2010010307387700
Number of Poles 3
Pollution Degree 3
RoHS Information 1SAA963006-4502
Dimension Diagram 1SAM300402F0002
Locked Rotor Amps (200 V AC) Three Phase 73.6 A
Mounting Position 1 ... 6
Product Net Width 45 mm
REACH Declaration 1SAA963005-4502
Tightening Torque Main Circuit 1.5 N·m
Product Net Height 97.8 mm
Product Net Weight 0.31 kg
I²t Characteristic 1SAM300507F0001
Package Level 1 EAN 4013614521584
Package Level 2 EAN 4013614523151
Rated Frequency (f) Main Circuit 50 Hz
Degree of Protection Housing IP20
Mounting on DIN Rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Customs Tariff Number 85362010
Electrical Durability 50000 cycle
Mechanical Durability 100000 cycle
Package Level 1 Units box 1 piece
Package Level 1 Width 92 mm
Package Level 2 Units carton 30 piece
Package Level 2 Width 280 mm
Wire Stripping Length Main Circuit 10 mm
Minimum Order Quantity 1 piece
Package Level 1 Height 50 mm
Package Level 2 Height 210 mm
Ambient Air Temperature Around the Enclosure 0 ... +40 °C
CAD Dimensional Drawing 2CDC001079B0201
End of Life Instructions 1SAC200332H0001
Full Load Amps Motor Use (200 V AC) Three Phase 11 A
Horsepower Rating UL/CSA (200 V AC) Three Phase 3 Hp
Instructions and Manuals 2CDC131034M6801
Recommended Screw Driver Pozidriv 2
Resistance to Vibrations 5g 3 ... 150 Hz
Tightening Torque UL/CSA Main Circuit 18 in·lb
General Use Rating UL/CSA (600 V AC) 16 A
Minimum Mounting Distance Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Operating Frequency (fsw) 0 ... 400 Hz
Rated Operational Voltage Main Circuit 690 V AC
Object Classification Code F
Product Net Depth / Length 86.55 mm
Contact Position Indication ON / OFF / TRIP
Package Level 1 Gross Weight 0.325 kg
Package Level 2 Gross Weight 13.386 kg
Rated Insulation Voltage (Ui) 690 V
Cut-off Current Characteristic 1SAM300508F0001
Declaration of Conformity - CE 1SAD101100-3407
Package Level 1 Depth / Length 102 mm
Package Level 2 Depth / Length 395 mm
Rated Operational Current (Ie) 16 A
Declaration of Conformity - CCC 2020980307003526
Connecting Capacity Main Circuit Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Declaration of Conformity - UKCA 1SAD201100-3407
Maximum Operating Voltage UL/CSA Main Circuit 600 V AC
Data Sheet, Technical Information 1SBC100200C02__
Instructions and Manuals (Part 2) 2CDC131060M0202
Rated Operational Power AC-3 (Pe) (400 V) Three Phase 7.5 kW
Time-Current Characteristic Curve 1SAM300515F0008
IDEA Granular Category Code (IGCC) 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers
Rated Operational Power AC-3e (Pe) (400 V) Three Phase 7.5 kW
Rated Operational Current AC-3 (Ie) 16 A
Short-Circuit Current Rating (SCCR) Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA
Toxic Substances Control Act - TSCA 2CMT2023-006539
Ambient Air Temperature Compensation No
Rated Operational Current AC-3e (Ie) 16 A
Maximum Operating Altitude Permissible 2000 m
Rated Impulse Withstand Voltage (Uimp) Main Circuit 6 kV
Connecting Capacity Main Circuit UL/CSA Flexible 1/2x 16-8 AWG
Resistance to Shock acc. to IEC 60068-2-27 11 ms Pulse 25g
Conflict Minerals Reporting Template (CMRT) 9AKK108467A5658
Conventional Free-air Thermal Current (Ith) Main Circuit 16 A
Shock and Vibration Withstand acc. to IEC 61373 Category 1, Class B
Rated Service Short-Circuit Breaking Capacity (Ics) (230 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (230 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (Ii) 200 A

Descrição do produto

MO132-16B Manual Motor Starter Magnetic Only 16 A
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top