Horário de atendimento: Segunda a sexta, das 9h às 18h.
3KL6230-1GB02 - 3KL6230-1GB02 SIEMENS Switch disconnector with fuse in new design Iu 800 A, Ue 690 V, 3-pole, for LV HRC fus..
Em estoque Produto em alta

3KL6230-1GB02

3KL6230-1GB02 SIEMENS Switch disconnector with fuse in new design Iu 800 A, Ue 690 V, 3-pole, for LV HRC fus..

$0.00 USD
4400 em estoque
Especificações principais
: Value
EAN: 4011209739352
UPC: 887621020972
ETIM: 4
Informações do fornecedor
SIEMENS
SIEMENS
Produtos: 367174
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Value
EAN 4011209739352
UPC 887621020972
ETIM 4
IDEA 4
Depth 240 mm
Notes Sucessor:3KF5380-0MF11, different dimensions, some deviating technical values.
Width 345 mm
Height 270 mm
UNSPSC 14
eClass 6
version Complete version with rotary operating mechanism
● 400V 50 kA
● 500V 50 kA
Group Code P360
Design type For mounting and installation
Fuse system LV HRC fuse
Price Group 12S
● maximum 55 °C
● minimum -25 °C
Metal Factor LAO-----
Mounting type Surface mounting and installation
Product Group 5853
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit 1 Piece
Commodity Code 85362090
Product family Not available
Net Weight (kg) 17,271 Kg
Operating power
number of poles 3
type of voltage AC/DC
Type of mounting fixed mounted
Country of origin Great Britain
Operating voltage
mounting position any
LKZ_FDB/ CatalogID LV10.1
PLM Effective Date Product phase-out since: 31.08.2018
Packaging Quantity 1
product brand name SENTRON
Packaging Dimension 376,00 x 371,00 x 298,00
Product Description Switch disconnector with fuse in new design Iu = 800 A, Ue = 690 V, 3-pole, for LV HRC fuses Sz. 3/2 with door operating mechanism 8UC7 Handle dark blue/blue-green Basic masking frame light gray
Product designation Switch disconnector
Protection class IP IP00
Design of the product With 3KL fuses
● AC-21 A / at 400 V 800 A
● AC-21 A / at 500 V 800 A
● AC-21 B / at 400 V 800 A
● AC-21 B / at 500 V 800 A
● AC-22 A / at 400 V 800 A
● AC-22 A / at 500 V 800 A
● AC-22 B / at 400 V 800 A
● AC-22 B / at 500 V 800 A
● stranded / maximum 480 mm²
Product Lifecycle (PLM) PM400:Phase Out Started
● at DC / rated value 440 V
General Product Approval Declaration of Conformity
Interlockable (EF006281) true
Export Control Regulations AL : N / ECCN : N
Number of poles (EF001391) 3
Size of disconnecting link 3 and 2
certificate of suitability UR
Product feature / interlock Yes
Standard lead time ex-works 15 Day/Days
Surcharge for Raw Materials None
Package size unit of measure MM
Number of switches (EF005586) -
Device construction (EF008240) Built-in device fixed built-in technique
Product Dimensions (W x L x H) Not available
Motor drive optional (EF007386) false
Operating current / rated value 800 A
Continuous current / rated value 800 A
Insulation voltage / rated value 1 000 V
Type of connection, main circuit flat pad connection, M12
Colour control element (EF007167) -
Design of the operating mechanism manual operating mechanism
Motor drive integrated (EF006697) false
Version as main switch (EF006981) true
● mounting type / rail mounting No
Rated operating voltage (EF001435) -
Type of control element (EF006976) Other
Switching power at 400 V (EF009166) -
Version as safety switch (EF006985) true
Voltage release optional (EF007491) false
Ambient temperature / during storage
Article Number (Market Facing Number) 3KL6230-1GB02
Rated permanent current Iu (EF001389) 800.0
● at AC / at 50/60 Hz / rated value 690 V
Ambient temperature / during operation
Degree of protection (NEMA) (EF011959) -
Design of the load switch / Strip form No
Suitable for floor mounting (EF007243) FALSE
Surge voltage resistance / rated value 8 000 V
Version as reversing switch (EF009408) -
WEEE (2012/19/EU) Take-Back Obligation Yes
Conditional rated short-circuit current
● at AC-23 A / at 500 V / rated value 400 000 W
Number of poles / for main current circuit 3
Operating current / at AC-21 / rated value 800 A
Type of the driving mechanism / motor drive No
● reference code / acc. to DIN EN 61346-2 Q
Max. rated operation voltage Ue AC (EF007355) 690
Suitable for front mounting 4-hole (EF007247) false
Suitable for front mounting centre (EF007248) false
Suitable for intermediate mounting (EF007264) false
Number of CO contacts / for auxiliary contacts 0
Number of NC contacts / for auxiliary contacts 0
Number of NO contacts / for auxiliary contacts 0
Rated operation power at AC-3, 400 V (EF001364) -
Degree of protection (IP), front side (EF003118) IP00
Rated operation power at AC-23, 400 V (EF007027) 400.0
● in utilization category / AC-21 A / at 400 V 50 kA
● in utilization category / AC-21 A / at 500 V 50 kA
● in utilization category / AC-21 B / at 400 V 50 kA
● in utilization category / AC-21 B / at 500 V 50 kA
● in utilization category / AC-22 A / at 400 V 50 kA
● in utilization category / AC-22 A / at 500 V 50 kA
● in utilization category / AC-22 B / at 400 V 50 kA
● in utilization category / AC-22 B / at 500 V 50 kA
Rated short-time withstand current lcw (EF007050) -
Version as emergency stop installation (EF006959) false
Version as maintenance-/service switch (EF006986) true
Rated permanent current at AC-21, 400 V (EF009165) -
Rated permanent current at AC-23, 400 V (EF011777) 800
Rated current Ie / maximum / in utilization category
Conditioned rated short-circuit current Iq (EF001444) -
● at AC-23 A / at 400 V / at 50/60 Hz / rated value 400 000 W
● at AC-23 A / at 690 V / at 50/60 Hz / rated value 500 000 W
Connectable conductor cross-section / for main contacts
Suitable for distribution board installation (EF007262) false
Type of electrical connection of main circuit (EF006819) Other
● Mounting type / front mounting with 4-hole attachment No
● Mounting type / front mounting with central attachment No
Number of auxiliary contacts as change-over contact (EF003531) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as normally closed contact (EF001377) 0
Compliance with the substance restrictions according to RoHS directive Since: 01.06.2007
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole 75 W
Let-through current / I2 t / maximum permissible / in utilization category / AC-22 B / at 400 V 10 500 000 A²·s
General Product ApprovalDeclaration of ConformityTest CertificatesShipping ApprovalotherSpecial Test CertificateEnvironmental Confirmations General Product Approval

Descrição do produto

More details
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top