3LD2015-0TK53 - 3LD2015-0TK53 SIEMENS SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 16 A, o..
Em estoque Produto em alta

3LD2015-0TK53

3LD2015-0TK53 SIEMENS SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 16 A, o..

$0.00 USD
3402 em estoque
Especificações principais
: Confirmation
EAN: 4011209538481
UPC: Not available
ETIM: 5
Informações do fornecedor
SIEMENS
SIEMENS
Produtos: 367174
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Confirmation
EAN 4011209538481
UPC Not available
ETIM 5
depth 393.5 mm
width 67 mm
UNSPSC 14
eClass 6
height 83 mm
● solid 1x (1...6mm²)
Group Code P360
net weight 377.61 g
● maximum 10
● minimum 18
Date5/3/2022
Metal Factor LAO-----
● stranded 1x (1..6mm²)
Miscellaneous
Product Group 5887
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit 1 Piece
Commodity Code 85365080
Product family Basic Devices
power loss [W]
type of device fixed mounting
type of switch Floor mounting with door coupling
Net Weight (kg) 0,384 Kg
number of poles 3
operating power
product feature
● main switch Yes
● motor drive No
design of handle rotary operating mechanism, red/yellow
fastening method Built-in unit fixed-mounted version
Country of origin Germany
● rail mounting Yes
● safety switch Yes
LKZ_FDB/ CatalogID LV10.1
Packaging Quantity 1
product brand name SENTRON
Packaging Dimension 87,00 x 420,00 x 75,00
Product Description SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 16 A, operating power / at AC-23 A 400 V: 7.5 kW, floor mounting with door coupling, rotary operating mechanism, Red / yellow, 4-hole mounting of the handle, without tolerance compensation
operational current
product designation 3LD Switch disconnector
protection class IP IP65
suitability for use
● voltage trigger No
design of the product EMERGENCY-STOP switch
Product Lifecycle (PLM) PM300:Active Product
design of the fuse link
special product feature Without tolerance compensation
● at AC / rated value 16 A
● switch disconnector Yes
General Product Approval Declaration of Conformity
Interlockable (EF006281) true
● EMERGENCY OFF switch Yes
● 4-hole front mounting Yes
● at AC-23 A / at 690 V 6 000
Export Control Regulations AL : N / ECCN : N
Number of poles (EF001391) 3
● for auxiliary contacts connection terminals
Standard lead time ex-works 80 Day/Days
Surcharge for Raw Materials None
size of switch disconnector 1
● at 40 °C / rated value 16 A
● at 45 °C / rated value 16 A
● at 50 °C / rated value 16 A
● at 55 °C / rated value 16 A
● per conductor / typical 1 W
Package size unit of measure MM
product extension / optional
● for main current circuit box terminal
Number of switches (EF005586) 1
operating frequency / maximum 50 1/h
type of electrical connection
● maintenance/repair switch Yes
Device construction (EF008240) Built-in device fixed built-in technique
type of fuse / according to UL RK5
Motor drive optional (EF007386) false
design of the actuating element Short rotary knob
color / of the actuating element red
degree of protection NEMA rating 1, 3R, 4X, 12
insulation voltage / rated value 690 V
Colour control element (EF007167) Red
Motor drive integrated (EF006697) false
Version as main switch (EF006981) true
number of bracket locks / maximum 3
operational current / rated value 16 A
Rated operating voltage (EF001435) -
Type of control element (EF006976) Short thumb-grip
protection class IP / on the front IP65
Switching power at 400 V (EF009166) -
Version as safety switch (EF006985) true
Voltage release optional (EF007491) false
● can be locked into OFF position Yes
● at AC-3 / at 240 V / rated value 3 kW
● at AC-3 / at 400 V / rated value 6 kW
● at AC-3 / at 690 V / rated value 5.5 kW
Article Number (Market Facing Number) 3LD2015-0TK53
Rated permanent current Iu (EF001389) 16.0
● at AC-21 / at 690 V / rated value 16 A
Degree of protection (NEMA) (EF011959) -
Suitable for floor mounting (EF007243) FALSE
Version as reversing switch (EF009408) false
WEEE (2012/19/EU) Take-Back Obligation Yes
ambient temperature / during operation
surge voltage resistance / rated value 6 kV
electrical endurance (switching cycles)
● at 690 V / by gG fuse / rated value 50 kA
● at AC-21 A / at 240 V / rated value 16 A
● at AC-21 A / at 440 V / rated value 16 A
● at AC-23 A / at 240 V / rated value 4 kW
● at AC-23 A / at 400 V / rated value 16 A
● at AC-23 A / at 440 V / rated value 7.5 kW
● at AC-23 A / at 690 V / rated value 8 kW
let-through current / with closed switch
● front mounting with central attachment No
type of the driving mechanism / motor drive No
Max. rated operation voltage Ue AC (EF007355) 690
Suitable for front mounting 4-hole (EF007247) true
Suitable for front mounting centre (EF007248) false
Suitable for intermediate mounting (EF007264) true
ambient temperature / during storage / minimum -25 °C
number of CO contacts / for auxiliary contacts 0
number of NC contacts / for auxiliary contacts 0
number of NO contacts / for auxiliary contacts 0
● finely stranded / with core end processing 1x (1...4mm²)
Rated operation power at AC-3, 400 V (EF001364) 5.5
hasp thickness / of the bracket locks / maximum 8 mm
hasp thickness / of the bracket locks / minimum 4 mm
Degree of protection (IP), front side (EF003118) IP65
Rated operation power at AC-23, 400 V (EF007027) 0.0075
Rated short-time withstand current lcw (EF007050) 0.34
Version as emergency stop installation (EF006959) true
Version as maintenance-/service switch (EF006986) true
Rated permanent current at AC-21, 400 V (EF009165) 16
Rated permanent current at AC-23, 400 V (EF011777) -
Region Specific PriceGroup / Headquarter Price Group 12R / 1CL
mechanical service life (switching cycles) / typical 100 000
operational current / of upstream fuse / rated value 20 A
Conditioned rated short-circuit current Iq (EF001444) -
Suitable for distribution board installation (EF007262) true
Type of electrical connection of main circuit (EF006819) Frame clamp
● at 440 V / for combination switch + gG fuse / maximum 3 kA
insulation voltage / of the auxiliary switch / rated value 500 V
continuous current / of the auxiliary contact / rated value 10 A
operating voltage / of auxiliary contacts / at AC / maximum 500 V
Number of auxiliary contacts as change-over contact (EF003531) 0
● for short-circuit protection of the main circuit / required fuse gL/gG: 20 A
Number of auxiliary contacts as normally open contact (EF001376) 0
display version / for switch position indicator manual operation 1 ON - 0 OFF
AWG number / as coded connectable conductor cross section / solid
Number of auxiliary contacts as normally closed contact (EF001377) 0
conditional short-circuit current / with line-side fuse protection
type of connectable conductor cross-sections / for copper conductor
● for short-circuit protection of the auxiliary switch / required fuse gL/gG: 10 A
continuous current / of upstream fuse / according to UL / rated value 50 A
type of connectable conductor cross-sections / for auxiliary contacts
● at 690 V / for combination switch + gG fuse / maximum permissible 3 kA
Compliance with the substance restrictions according to RoHS directive Given
REACH Art. 33 Duty to inform according to the current list of candidates Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
operational current / at AC / according to UL 508/UL 60947-4-1 / rated value 16 A
● for rated value of the current / at AC / in hot operating state / per pole 0.5 W
number of connectable CO contacts / for auxiliary contacts / attachable / maximum 0
number of connectable NC contacts / for auxiliary contacts / attachable / maximum 3
number of connectable NO contacts / for auxiliary contacts / attachable / maximum 5
short-time withstand current (SCCR) / at 600 V / according to UL 508/UL 60947-4-1 5 kA
active power [hp] / at AC / at 480 V / according to UL 508/UL 60947-4-1 / rated value 7.5
active power [hp] / at AC / at 600 V / according to UL 508/UL 60947-4-1 / rated value 10
I2t value / with closed switch / at 690 V / for combination switch + gG fuse / maximum 3 kA2.s
operating voltage / at AC / at 50/60 Hz / according to UL 508/UL 60947-4-1 / rated value 600 V
let-through I2t value / with closed switch / at 440 V / for combination switch + gG fuse / maximum 2.5 kA2.s
General Product ApprovalConfirmationMiscellaneousGeneral Product ApprovalDeclaration of ConformityTest CertificatesMarine / ShippingotherUK Declaration of ConformitySpecial Test CertificateEnvironmental ConfirmationsotherMiscellaneous General Product Approval

Descrição do produto

INTERR. PPAL./P. EMERG. 3 poles IU=16, P/AC-23A WITH 400V=7.5KW FIXATION IN BASE FIXATION PROFILE/TWO ROTARY MYO HOLES RED/YELLOW FIXING FOUR TALDROS. Manufactured to order. Non-Cancelable Non-Returna
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top