Horário de atendimento: Segunda a sexta, das 9h às 18h.
3LD2530-0TK01-0AB5 - 3LD2530-0TK01-0AB5 SIEMENS SENTRON, Switch disconnector 3LD, main switch, 3-pole, Iu: 63 A, Operating power ..
Em estoque Produto em alta

3LD2530-0TK01-0AB5

3LD2530-0TK01-0AB5 SIEMENS SENTRON, Switch disconnector 3LD, main switch, 3-pole, Iu: 63 A, Operating power ..

$0.00 USD
4286 em estoque
Especificações principais
: Confirmation
EAN: 4011209547889
UPC: Not available
depth: 90 mm
Informações do fornecedor
SIEMENS
SIEMENS
Produtos: 367174
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Confirmation
EAN 4011209547889
UPC Not available
depth 90 mm
width 63 mm
height 82 mm
● solid 1x (2,5...35mm²)
Group Code P360
net weight 2 831 g
● maximum 6
● minimum 14
Date5/2/2022
Metal Factor LAO-----
● stranded 1x (2,5..35mm²)
Miscellaneous
Product Group 5887
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit 1 Piece
Commodity Code 85365080
Product family Not available
power loss [W]
type of device fixed mounting
type of switch DIN-rail mounting
Net Weight (kg) 2,760 Kg
number of poles 3
operating power
product feature
● main switch Yes
● motor drive No
design of handle knob-operated mechanism, black
fastening method Built-in unit fixed-mounted version
Country of origin Germany
● rail mounting Yes
● safety switch Yes
LKZ_FDB/ CatalogID LV10.1
Packaging Quantity 1
product brand name SENTRON
Packaging Dimension 150,00 x 201,00 x 155,00
Product Description SENTRON, Switch disconnector 3LD, main switch, 3-pole, Iu: 63 A, Operating power / at AC-23 A at 400 V: 22 kW, installation in distribution boards, knob-operated mechanism, black, handle direct at the switch
operational current
product designation 3LD Switch disconnector
protection class IP IP40
suitability for use
● voltage trigger No
design of the product Main switch
Minimum order quantity 10
Product Lifecycle (PLM) PM300:Active Product
design of the fuse link
● at AC / rated value 63 A
● switch disconnector Yes
General Product Approval Declaration of Conformity
● EMERGENCY OFF switch No
● 4-hole front mounting No
● at AC-23 A / at 690 V 6 000
Export Control Regulations ECCN : N / AL : N
● for auxiliary contacts connection terminals
Standard lead time ex-works 80 Day/Days
Surcharge for Raw Materials None
size of switch disconnector 3
● at 40 °C / rated value 63 A
● at 45 °C / rated value 63 A
● at 50 °C / rated value 63 A
● at 55 °C / rated value 63 A
● per conductor / typical 5 W
Package size unit of measure MM
product extension / optional
● for main current circuit box terminal
operating frequency / maximum 50 1/h
type of electrical connection
● maintenance/repair switch Yes
type of fuse / according to UL RK5
design of the actuating element selector switch
color / of the actuating element black
insulation voltage / rated value 690 V
number of bracket locks / maximum 2
operational current / rated value 63 A
protection class IP / on the front IP40
● can be locked into OFF position Yes
● at AC-3 / at 240 V / rated value 11 kW
● at AC-3 / at 400 V / rated value 19 kW
● at AC-3 / at 690 V / rated value 15 kW
Article Number (Market Facing Number) 3LD2530-0TK01-0AB5
● at AC-21 / at 690 V / rated value 63 A
WEEE (2012/19/EU) Take-Back Obligation Yes
ambient temperature / during operation
surge voltage resistance / rated value 6 kV
electrical endurance (switching cycles)
● at 690 V / by gG fuse / rated value 50 kA
● at AC-21 A / at 240 V / rated value 63 A
● at AC-21 A / at 440 V / rated value 63 A
● at AC-23 A / at 240 V / rated value 11 kW
● at AC-23 A / at 400 V / rated value 43 A
● at AC-23 A / at 440 V / rated value 22 kW
● at AC-23 A / at 690 V / rated value 19 kW
let-through current / with closed switch
● front mounting with central attachment No
type of the driving mechanism / motor drive No
ambient temperature / during storage / minimum -25 °C
number of CO contacts / for auxiliary contacts 0
number of NC contacts / for auxiliary contacts 0
number of NO contacts / for auxiliary contacts 0
● finely stranded / with core end processing 1x (2.5...16 mm²)
hasp thickness / of the bracket locks / maximum 6 mm
hasp thickness / of the bracket locks / minimum 4 mm
Region Specific PriceGroup / Headquarter Price Group 12R / 1CL
mechanical service life (switching cycles) / typical 100 000
operational current / of upstream fuse / rated value 63 A
● at 440 V / for combination switch + gG fuse / maximum 6 kA
insulation voltage / of the auxiliary switch / rated value 500 V
continuous current / of the auxiliary contact / rated value 10 A
operating voltage / of auxiliary contacts / at AC / maximum 500 V
● for short-circuit protection of the main circuit / required fuse gL/gG: 63 A
display version / for switch position indicator manual operation 1 ON - 0 OFF
AWG number / as coded connectable conductor cross section / solid
conditional short-circuit current / with line-side fuse protection
type of connectable conductor cross-sections / for copper conductor
● for short-circuit protection of the auxiliary switch / required fuse gL/gG: 10 A
continuous current / of upstream fuse / according to UL / rated value 175 A
type of connectable conductor cross-sections / for auxiliary contacts
● at 690 V / for combination switch + gG fuse / maximum permissible 6 kA
Compliance with the substance restrictions according to RoHS directive Given
REACH Art. 33 Duty to inform according to the current list of candidates Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
operational current / at AC / according to UL 508/UL 60947-4-1 / rated value 63 A
● for rated value of the current / at AC / in hot operating state / per pole 4.5 W
number of connectable CO contacts / for auxiliary contacts / attachable / maximum 0
number of connectable NC contacts / for auxiliary contacts / attachable / maximum 2
number of connectable NO contacts / for auxiliary contacts / attachable / maximum 4
short-time withstand current (SCCR) / at 600 V / according to UL 508/UL 60947-4-1 5 kA
active power [hp] / at AC / at 480 V / according to UL 508/UL 60947-4-1 / rated value 40
active power [hp] / at AC / at 600 V / according to UL 508/UL 60947-4-1 / rated value 50
I2t value / with closed switch / at 690 V / for combination switch + gG fuse / maximum 21 kA2.s
operating voltage / at AC / at 50/60 Hz / according to UL 508/UL 60947-4-1 / rated value 600 V
let-through I2t value / with closed switch / at 440 V / for combination switch + gG fuse / maximum 21 kA2.s
General Product ApprovalConfirmationMiscellaneousGeneral Product ApprovalDeclaration of ConformityTest CertificatesMarine / ShippingotherUK Declaration of ConformitySpecial Test CertificateEnvironmental ConfirmationsotherMiscellaneous General Product Approval

Descrição do produto

INTERR. PPAL. 3 POLES IU=63, P/AC-23A WITH 400V=22KW FIXATION BASED FIXING PROFILE/2 HOLES MULETILLA NETAMA LOGO JANSSEN CONSISTS OF 10 INTERR: ( ** ATTENTION : Price per 1 Unit and Minimum Quantity /
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top