Especificações principais
: 50 V DC (UL 1077)
Fuse: F1 (fast blow)
Type: Male
Color: gray (RAL 7042)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
50 V DC (UL 1077)
Fuse F1 (fast blow)
Type Male
Color gray (RAL 7042)
Depth 52 mm
Width 12.3 mm
Height 45 mm
General When mounted in rows, the nominal device current can be limited to just 80% or must be overdimensioned accordingly.
Fuse type Automatic device
Product type Thermomagnetic device circuit breakers
Voltage drop 0.13 V (at 1 x In)
Humidity test 240 h, 95 % RH, 40 °C
Mounting type on base element
Rated voltage 50 V DC (IEC 60934)
Identification UL Listed UL 508
Product family CB TM
Tripping level Trip-free mechanism (positive)
No. of channels 1
Open side panel No
Tripping method TM (thermomagnetic)
Article revision 06
Rated current IN 10 A (IEC 60934)
Auxiliary circuit 277 V AC / 0.5 A (Low-induction)
Connection method pluggable
Device resistance 13 mΩ
Power dissipation 2 W (in nominal operation per channel)
Shock (operation) 15g (IEC 60068-2-27, Test Ea)
Type of actuation S type
Degree of pollution 2
Dielectric strength 3000 V AC (Actuation area)
Dimensional drawing
Number of positions 1
Rated surge voltage 2.5 kV (Increased insulation in actuation area)
Degree of protection IP30 (Actuation area)
Required backup fuse 40 A (I > Icn)
Complete module depth 77.3 mm
Complete module width 12.3 mm
Vibration (operation) 5g (IEC 60068-2-6, Test Fc)
Complete module height 90 mm
Switching cycles, max. 6000 (at 1 x In)
Standards/specifications EN 60934
Insulating material group II
Insulation resistance Riso > 100 MΩ (500 V DC)
Max. operating current Imax 1 A
Rated insulation voltage Ui 277 V AC (UL 1077)
Minimum operating current Imin 10 mA
Ambient temperature (operation) -30 °C ... 60 °C
Maximum operating voltage UmaxDC 240 V
Minimum operating voltage UminDC 10 V
Short-circuit switching capacity 1000 A AC (277 V AC)
Maximum operating voltage Umax.AC 240 V
Flammability rating according to UL 94 V-0
Ambient temperature (storage/transport) -40 °C ... 80 °C
Rated short-circuit switching capacity Icn 600 A (50 V DC)

Descrição do produto

Interrupt. protec. thermomagnetic, 1 pole, caract curve. activ. F1 (fast), 1 inverted contact, connector for base element.