Horário de atendimento: Segunda a sexta, das 9h às 18h.
CLOUD IOT GATEWAY - CLOUD IOT GATEWAY 1031235 PHOENIX CONTACT IoT gateway
Em estoque Produto em alta

CLOUD IOT GATEWAY

CLOUD IOT GATEWAY 1031235 PHOENIX CONTACT IoT gateway

$0.00 USD
3148 em estoque
Especificações principais
GTIN: 4055626534169
Note: Made to Order (non-returnable)
Orderkey: 1031235
Packing unit: 1 pc
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4055626534169
Note Made to Order (non-returnable)
Orderkey 1031235
Packing unit 1 pc
Country of origin DE (Germany)
Shock (Dimensions) 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
Custom tariff number 85176200
Processor (Power supply) ARM®Cortex®-A8 1x 600 MHz
Number (Mechanical design) 1
Depth (Key Commercial Data) 114.5 mm
Weight (Ambient conditions) 144.5 g
Width (Key Commercial Data) 22.5 mm
(Standards and Regulations) No hazardous substances above threshold values
Height (Key Commercial Data) 99 mm
Interface (Mechanical design) Service
Realtime clock (General data) Yes
Shock (IEC 61131 runtime system) 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
Supply voltage (Data interfaces) 24 V DC -20 % / +15 %
Degree of protection (Dimensions) IP20
Weight per Piece (excluding packing) 144.500 g
Air pressure (operation) (Dimensions) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Connection method (Mechanical design) USB type C
China RoHS (Standards and Regulations) Environmentally friendly use period: unlimited = EFUP-e
Supply voltage range (Data interfaces) 18 V DC ... 30 V DC
Transmission speed (Mechanical design) 100 Mbps
Immunity to EF (IEC 61131 runtime system) Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Immunity to ESD (IEC 61131 runtime system) Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Ambient temperature (operation) (Dimensions) -25 °C ... 55 °C up to 2000 m above mean sea level
Immunity to burst (IEC 61131 runtime system) Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
Immunity to surge (IEC 61131 runtime system) Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
Shock (operation) (IEC 61131 runtime system) 10g (Bump endurance test according to EN 60068-2-29)
Air pressure (storage/transport) (Dimensions) 58 kPa ... 106 kPa (up to 4500 m above mean sea level)
Permissible humidity (operation) (Dimensions) 30 % ... 95 % (according to DIN EN 61131-2)
Typical current consumption (Data interfaces) 200 mA
Interference emission (IEC 61131 runtime system) Noise emission test according to EN 61000-6-3 Class B
Note on weight specifications (Ambient conditions) with connectors
Ambient temperature (storage/transport) (Dimensions) -25 °C ... 85 °C
Permissible humidity (storage/transport) (Dimensions) 5 % ... 95 %
Electromagnetic compatibility (IEC 61131 runtime system) Conformance with EMC Directive 2014/30/EU
Immunity to conducted interference (IEC 61131 runtime system) Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V

Descrição do produto

Cloud IoT gateway for integration of new and existing installations without additional engineering tasks. By easily integrating processes with protocols such as Modbus/TCP, sensor and process data are
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top