Horário de atendimento: Segunda a sexta, das 9h às 18h.
PSR-MC32-3NO-1NC-24-230UC-SC - PSR-MC32-3NO-1NC-24-230UC-SC 2700524 PHOENIX CONTACT Safety relays
Em estoque Produto em alta

PSR-MC32-3NO-1NC-24-230UC-SC

PSR-MC32-3NO-1NC-24-230UC-SC 2700524 PHOENIX CONTACT Safety relays

$0.00 USD
3725 em estoque
Especificações principais
GTIN: 4046356912693
Orderkey: 2700524
Catalog page: Page 253 (C-6-2017)
Depth (Note): 114.5 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4046356912693
Orderkey 2700524
Catalog page Page 253 (C-6-2017)
Depth (Note) 114.5 mm
Packing unit 1 pc
Width (Note) 22.5 mm
Height (Note) 112.2 mm
(Power supply) Test pulse rate = 5 x Test pulse width
(Digital inputs) 4 A gL/gG (for low-demand applications)
Country of origin DE (Germany)
Net weight (Times) 243.8 g
Relay type (Times) Electromechanical relay with forcibly guided contacts in accordance with EN 50205
pluggable (General) Yes
Custom tariff number 85371098
(Ambient conditions) 2.9 W (with AC)
Housing color (Times) yellow
Mounting type (Times) DIN rail mounting
Screw thread (General) M3
Status display (Times) 3 x green LED
Housing material (Times) PBT
Mounting position (Times) vertical or horizontal
Category (Connection data) 4
Filter time (Power supply) max. 1.5 ms (to S10-S12; test pulse width; at 24 V DC)
Stripping length (General) 7 mm
Connection method (General) Screw connection
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Degree of protection (Times) IP20
Output fuse (Digital inputs) 6 A gL/gG
Output name (Digital inputs) Enabling current path
Assembly instructions (Times) See derating curve
Contact type (Digital inputs) 3 enabling current paths
Designation (Connection data) EN 62061
Inrush current (Power supply) < 5 mA (with Us/Ixat S10/S12/S13)
Maximum altitude (Dimensions) ≤ 2000 m (Above sea level)
Nominal operating mode (Times) 100% operating factor
Inrush current (Digital inputs) min. 10 mA
Stop category (Connection data) 0
Filter time (Ambient conditions) 2 ms (at A1 in the event of voltage dips at Us)
Contact material (Digital inputs) AgSnO2
Operating voltage display (Times) 1 x green LED
Type of protection (Power supply) Inputs: protection against polarity reversal, surge protection
Current consumption (Power supply) < 5 mA (at Us/Ixto S10/S12/S13/S34/S35)
Number of outputs (Digital inputs) 3 (undelayed)
Sq. Total current (Digital inputs) 72 A2(observe derating)
Switching voltage (Digital inputs) min. 5 V AC/DC
Apparent power (Ambient conditions) typ. 5 VA (at US)
Inrush current (Ambient conditions) < 80 A (Δt = 50 µs at Us)
Output description (Digital inputs) safety-related N/O contacts
Switching capacity (Digital inputs) min. 50 mW
Concurrence input 1/2 (Power supply)
Switching frequency (Digital inputs) max. 1 Hz
Weight per Piece (excluding packing) 243.800 g
(Safety-related characteristic data) Safe isolation, reinforced insulation 6 kV between all other circuits
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
(Relay outputs: enabling current path) 4 A gL/gG (for low-demand applications)
Protective circuit (Ambient conditions) US: surge protection 275 V varistor / 411 V suppressor diode
Mechanical service life (Digital inputs) 10x 106cycles
Performance level (PL) (Connection data) e
Conductor cross section AWG max. (General) 12
Conductor cross section AWG min. (General) 24
Shock (Safety-related characteristic data) 15g
Protective circuit/component (Power supply) 38.6 V suppressor diode
Ambient temperature (operation) (Dimensions) -40 °C ... 55 °C (observe derating)
Conductor cross section solid max. (General) 2.5 mm²
Conductor cross section solid min. (General) 0.2 mm²
Limiting continuous current (Digital inputs) 6 A (observe derating)
Power consumption at US (Ambient conditions) 2.7 W (with DC)
Input current range "0" signal (Power supply) 0 mA ... 2 mA (for safe Off; at S10/S12/S13)
Input voltage range "0" signal (Power supply) 0 V DC ... 5 V DC (for safe Off; at S10/S12/S13)
Utilization restriction (Key Commercial Data) 1
Safety Integrity Level (SIL) (Connection data) 3
Conductor cross section flexible max. (General) 2.5 mm²
Conductor cross section flexible min. (General) 0.2 mm²
Conformance (Safety-related characteristic data) CE-compliant
Designation (Safety-related characteristic data) Air clearances and creepage distances between the power circuits
Output fuse (Relay outputs: enabling current path) 6 A gL/gG
Output name (Relay outputs: enabling current path) Signaling current path
Contact type (Relay outputs: enabling current path) 1 signaling current path
Min. degree of protection of inst. location (Times) IP54
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 85 °C
Rated control supply current IS (Ambient conditions) typ. 103 mA (24 V DC)
Inrush current (Relay outputs: enabling current path) min. 10 mA
Interrupting rating (ohmic load) max. (Digital inputs) 1500 VA (250 V AC, τ = 0 ms)
(Relay outputs: return current/signaling current path) < 100 ms (manual, monitored start)
Contact material (Relay outputs: enabling current path) AgSnO2
Degree of pollution (Safety-related characteristic data) 2
Number of outputs (Relay outputs: enabling current path) 1 (undelayed)
Switching voltage (Relay outputs: enabling current path) min. 5 V AC/DC
Output description (Relay outputs: enabling current path) non-safety-related N/C contact
Overvoltage category (Safety-related characteristic data) III
Switching capacity (Relay outputs: enabling current path) min. 50 mW
Max. permissible humidity (storage/transport) (Dimensions) 75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data) DIN EN 50178; EN 60947-5-1
Switching frequency (Relay outputs: enabling current path) 1 Hz
Vibration (operation) (Safety-related characteristic data) 10 Hz ... 150 Hz, 2g
Voltage at input/start and feedback circuit (Power supply) 24 V DC -20 % / +25 %
Max. permissible relative humidity (operation) (Dimensions) 75 % (on average, 85% infrequently, non-condensing)
Max. permissible overall conductor resistance (Power supply) 150 Ω
Rated control circuit supply voltage US (Ambient conditions) 24 V AC/DC ... 230 V AC/DC -15 % / +10 %
Maximum interrupting rating (inductive load) (Digital inputs) 48 W (24 V DC, τ = 40 ms)
Rated insulation voltage (Safety-related characteristic data) 250 V AC
Safety Integrity Level Claim Limit (SIL CL) (Connection data) 3
Mechanical service life (Relay outputs: enabling current path) 10x 106cycles
Switching capacity according to IEC 60947-5-1 (Digital inputs) 5 A (24 V (DC13))
Limiting continuous current (Relay outputs: enabling current path) 6 A
Rated surge voltage/insulation (Safety-related characteristic data) Basic insulation 4 kV between enabling current path (23/24) and enabling current path (33/34) and signaling current path (41/42)
Restart time (Relay outputs: return current/signaling current path) < 1 s
Recovery time (Relay outputs: return current/signaling current path) < 500 ms
Typical pickup time at US (Relay outputs: return current/signaling current path) < 200 ms (when controlled via A1)
Typical release time at US (Relay outputs: return current/signaling current path) < 20 ms (when actuation is via the sensor circuit)
Typical response time at US (Relay outputs: return current/signaling current path) < 150 ms (automatic start)

Descrição do produto

Safety relay for emergency stop, protection doors and light curtain up to SIL3, cat.4, PLe, 1 or 2 channel service, automatic or manual monitored start, 3 trip circuits, 1 warning current circuit, US=
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top