Horário de atendimento: Segunda a sexta, das 9h às 18h.
PSR-PC32-2NO-1NC-24-230UC-SP - PSR-PC32-2NO-1NC-24-230UC-SP 2700582 PHOENIX CONTACT Coupling relay
Em estoque Produto em alta

PSR-PC32-2NO-1NC-24-230UC-SP

PSR-PC32-2NO-1NC-24-230UC-SP 2700582 PHOENIX CONTACT Coupling relay

$0.00 USD
4916 em estoque
Especificações principais
: High demand
Depth: 114.5 mm
Shock: 15g
Width: 17.5 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
High demand
Depth 114.5 mm
Shock 15g
Width 17.5 mm
Height 117.4 mm
pluggable yes
CCCex note Use in potentially explosive areas is not permitted in China.
Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Application Safe switch off
Certificate UL 22 ATEX 2912X
Designation A1/A2
Filter time 10 ms (24 V DC, A1 in the event of voltage dips at Us)
Output fuse 6 A gL/gG
Product type Coupling relay
Assembly note See derating curve
Mounting type DIN rail mounting
Recovery time < 500 ms
Stop category 0
Apparent power typ. 4.1 VA
Identification  II 3G  Ex ec nC IIC T4 Gc
Inrush current typ. 16 A (Δt s)
Product family PSRmini
Status display 1 x LED (green), 1 x LED (yellow)
Color (Housing) yellow (RAL 1018)
Article revision 04
Contact material AgSnO2
Housing material Polyamide
Maximum altitude ≤ 2000 m (Above sea level)
Stripping length 8 mm
Connection method Push-in connection
Mounting position vertical or horizontal
Number of outputs 2 (undelayed)
Sq. Total current 72 A2(observe derating)
Switching voltage min. 12 V AC/DC
Output description safety-related N/O contacts
Protective circuit Surge protection; Varistor 275 V
Switching capacity min. 60 mW
Input current at UD < 5 mA (at terminal blocks 24V/GND at UD)
Note on application Only for industrial use
Switching frequency max. 1 Hz
Degree of protection IP20
Typical release time < 200 ms (with Uswhen controlled via A1)
Standards/regulations EN 60664-1, EN 60079-7, EN 60079-15
Typical response time < 100 ms (with Uswhen controlled via A1)
Vibration (operation) 10 Hz ... 150 Hz, 2g
Contact switching type 2 enabling current paths
Nominal operating mode 100% operating factor
Mechanical service life 10x 106cycles
Power consumption at US 1.8 W (with DC)
Rated insulation voltage 250 V AC
Operating voltage display 1 x yellow LED
Conductor cross-section AWG 24 ... 16
Limiting continuous current 6 A (observe derating)
Diagnostic supply voltage UD 24 V DC -15 % / +10 %
Safety Integrity Level (SIL) 3 (Reference IEC 61508)
Conductor cross section rigid 0.2 mm² ... 1.5 mm²
Rated surge voltage/insulation Basic insulation 4 kV between all current paths and housing
Ambient temperature (operation) -40 °C ... 70 °C (observe derating)
Rated control supply current IS 75 mA (24 V DC)
Conductor cross section flexible 0.2 mm² ... 1.5 mm²
Switching capacity (360/h cycles) 4 A (24 V (DC13))
Ambient temperature (storage/transport) -40 °C ... 85 °C
Rated control circuit supply voltage US 24 V AC/DC ... 230 V AC/DC -15 % ... +10 %
Min. degree of protection of inst. location IP54
Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
Maximum power dissipation for nominal condition 5.7 W (at US= 42 V AC, IL² = 72 A²)
Conductor cross section, flexible, with ferrule, with plastic sleeve 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross section flexible, with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)

Descrição do produto

Coupling relay for high and low demand applications SIL 3, couples digital signals to the periphery, wide input range of 24 V... 230 V, 2 trip circuits (1x up to 60 V, 1x up to 250 V), 1 feedback circ
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação