Horário de atendimento: Segunda a sexta, das 9h às 18h.
PSR-PC40-2NO-1DO-24DC-SP - PSR-PC40-2NO-1DO-24DC-SP 2700589 PHOENIX CONTACT Coupling relay
Em estoque Produto em alta

PSR-PC40-2NO-1DO-24DC-SP

PSR-PC40-2NO-1DO-24DC-SP 2700589 PHOENIX CONTACT Coupling relay

$0.00 USD
4869 em estoque
Especificações principais
GTIN: 4046356916141
Orderkey: 2700589
Catalog page: Page 283 (C-6-2017)
Depth (Note): 114.5 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4046356916141
Orderkey 2700589
Catalog page Page 283 (C-6-2017)
Depth (Note) 114.5 mm
Packing unit 1 pc
Width (Note) 12.5 mm
Height (Note) 116.6 mm
(Digital inputs) 4 A gL/gG (for low-demand applications)
Country of origin DE (Germany)
Indication (Times) 1 x red LED
Net weight (Times) 196 g
Relay type (Times) Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205)
pluggable (General) Yes
Custom tariff number 85364900
(Ambient conditions) ≥ 100 ms (at A1-A2; test pulse rate)
Housing color (Times) yellow
Mounting type (Times) DIN rail mounting
Status display (Times) 2 x green LEDs
Housing material (Times) PBT
Input name (Power supply) Start circuit
Mounting position (Times) vertical, horizontal, with front of module upward
Stripping length (General) 8 mm
Connection method (General) Spring-cage connection
(Standards and Regulations) No hazardous substances above threshold values
Degree of protection (Times) IP20
Output fuse (Digital inputs) 6 A gL/gG
Output name (Digital inputs) Enabling current path
Assembly instructions (Times) See derating curve
Contact type (Digital inputs) 2 enabling current paths
Designation (Connection data) EN 50156
Inrush current (Power supply) < 10 mA
Maximum altitude (Dimensions) ≤ 2000 m (Above sea level)
Recovery time (Alarm outputs) 500 ms
Nominal operating mode (Times) 100% operating factor
Inrush current (Digital inputs) min. 3 mA
Number of inputs (Power supply) 2 (Non-safety-related start inputs: Y1/Y2)
Stop category (Connection data) 0
Filter time (Ambient conditions) max. 2 ms (at A1-A2; test pulse width)
Contact material (Digital inputs) AgSnO2
Operating voltage display (Times) 1 x yellow LED
Current consumption (Power supply) < 5 mA
Number of outputs (Digital inputs) 2 (safety-related N/O contacts: 13/14, 23/24)
Sq. Total current (Digital inputs) 60 A2(observe derating)
Switching voltage (Digital inputs) min. 12 V AC/DC
Inrush current (Ambient conditions) typ. 400 mA (Δt s)
Output description (Digital inputs) 2 NO contacts each in series, without delay, floating
Switching capacity (Digital inputs) min. 60 mW
Switching frequency (Digital inputs) max. 0.5 Hz
Weight per Piece (excluding packing) 196.000 g
(Safety-related characteristic data) Class I, Div. 2, Groups A, B, C, D, T4
China RoHS (Standards and Regulations) Environmentally friendly use period: unlimited = EFUP-e
REACh SVHC (Standards and Regulations) Lead 7439-92-1
GL (Safety-related characteristic data) C, EMC2
Protective circuit (Ambient conditions) Serial protection against polarity reversal 33 V suppressor diode
Mechanical service life (Digital inputs) 10x 106cycles
Typical pickup time at US (Alarm outputs) < 200 ms (when controlled via A1, automatic start)
Conductor cross section AWG max. (General) 16
Conductor cross section AWG min. (General) 24
Shock (Safety-related characteristic data) 15g
Typical release time at US (Alarm outputs) < 35 ms (when controlled via A1)
Ambient temperature (operation) (Dimensions) -40 °C ... 70 °C (observe derating)
Conductor cross section solid max. (General) 1.5 mm²
Conductor cross section solid min. (General) 0.2 mm²
Limiting continuous current (Digital inputs) 6 A (High demand)
Power consumption at US (Ambient conditions) typ. 1.8 W
Utilization restriction (Key Commercial Data) EMC: class A product, see manufacturer's declaration in the download area
Current (Relay outputs: enabling current path) max. 100 mA
Safety Integrity Level (SIL) (Connection data) 3
Voltage (Relay outputs: enabling current path) approx. 22 V DC (Us- 2 V)
Conductor cross section flexible max. (General) 1.5 mm²
Conductor cross section flexible min. (General) 0.2 mm²
Conformance (Safety-related characteristic data) CE-compliant
Designation (Safety-related characteristic data) Air clearances and creepage distances between the power circuits
Output fuse (Relay outputs: enabling current path) 150 mA fast blow
Min. degree of protection of inst. location (Times) IP54
UL, USA/Canada (Safety-related characteristic data) cULus
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 85 °C
Rated control supply current IS (Ambient conditions) typ. 75 mA (depending on load M1 +100 mA)
Degree of pollution (Safety-related characteristic data) 2
Number of outputs (Relay outputs: enabling current path) 1 (non-safety-related)
Output description (Relay outputs: enabling current path) PNP
Overvoltage category (Safety-related characteristic data) III
Max. permissible humidity (storage/transport) (Dimensions) 75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data) DIN EN 50178, EN 60079-15
Vibration (operation) (Safety-related characteristic data) 2g
Voltage at input/start and feedback circuit (Power supply) 24 V DC -15 % / +10 %
Max. permissible relative humidity (operation) (Dimensions) 75 % (on average, 85% infrequently, non-condensing)
Max. permissible overall conductor resistance (Power supply) 150 Ω
Rated control circuit supply voltage US (Ambient conditions) 24 V DC -15 % / +10 % (A1/A2)
Maximum inrush current (Relay outputs: enabling current path) 500 mA (Δt = 1 ms at Us)
Rated insulation voltage (Safety-related characteristic data) 250 V AC
Switching capacity according to IEC 60947-5-1 (Digital inputs) 4 A (24 V (DC13))
Short-circuit protection (Relay outputs: enabling current path) no
Environmental simulation test (Safety-related characteristic data) ISA-S71.04 (G3)
Rated surge voltage/insulation (Safety-related characteristic data) Safe isolation, 6 kV reinforced insulation from control circuit, start circuit, signal output to the enabling current paths, 4 kV/basic insulation between the enabling current paths and between all current paths and housing

Descrição do produto

SIL 3 coupling relay for high and low demand applications, couples digital output signals to the periphery, 2 trip circuits, 1 digital signal output, Safe State Off applications, test pulse filter, pl
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top