Horário de atendimento: Segunda a sexta, das 9h às 18h.
PT-IQ-2X2-12DC-UT - PT-IQ-2X2-12DC-UT 2800984 PHOENIX CONTACT Surge protection device
Em estoque Produto em alta

PT-IQ-2X2-12DC-UT

PT-IQ-2X2-12DC-UT 2800984 PHOENIX CONTACT Surge protection device

$0.00 USD
4022 em estoque
Especificações principais
GTIN: 4046356665728
Note: Made to Order (non-returnable)
Orderkey: 2800984
Catalog page: Page 97 (C-4-2017)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4046356665728
Note Made to Order (non-returnable)
Orderkey 2800984
Catalog page Page 97 (C-4-2017)
Packing unit 1 pc
Country of origin DE (Germany)
(Connection data) EN 61000-6-3 2005
Custom tariff number 85363010
Altitude (Dimensions) ≤ 4000 m (amsl (above mean sea level))
Type (Ambient conditions) DIN rail module, two-section, divisible
(Additional descriptions) D1 - 2.5 kA
Color (Ambient conditions) jet black RAL 9005
Depth (Key Commercial Data) 77.5 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data) 17.7 mm
Height (Key Commercial Data) 91 mm
Degree of protection (Dimensions) IP20
Screw thread (Protective circuit) M3
Mounting type (Ambient conditions) DIN rail: 35 mm
Weight per Piece (excluding packing) 120.000 g
Housing material (Ambient conditions) PA 6.6
Stripping length (Protective circuit) 8 mm
Connection method (Protective circuit) Screw connection
Horizontal pitch (Key Commercial Data) 1 Div.
REACh SVHC (Standards and Regulations) Lead 7439-92-1
Tightening torque (Protective circuit) 0.5 Nm
Rated current (Additional descriptions) 700 mA (50 °C)
Direction of action (Ambient conditions) Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Standards/specifications (Connection data) IEC 61643-21 2000 + A1:2008, modified
Ambient temperature (operation) (Dimensions) -40 °C ... 70 °C
Nominal current IN (Additional descriptions) 700 mA (50 °C)
Nominal voltage UN (Additional descriptions) 12 V DC
Capacity (line-line) (Additional descriptions) typ. 4 nF
Residual current IPE (Additional descriptions) ≤ 2 µA (per signal circuit)
Resistance in series (Additional descriptions) 1.2 Ω ±5 %
Conductor cross section AWG (Protective circuit) 24 ... 12
IEC test classification (Additional descriptions) C1
Conductor cross section solid (Protective circuit) 0.2 mm² ... 4 mm²
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 85 °C
Input attenuation aE, sym. (Additional descriptions) typ. 0.3 dB (≤ 95 kHz/150 Ω)
Max. required back-up fuse (Additional descriptions) 800 mA (FF)
Conductor cross section flexible (Protective circuit) 0.2 mm² ... 2.5 mm²
Response time tA(line-line) (Additional descriptions) ≤ 1 ns
Pulse reset time (line-line) (Additional descriptions) ≤ 25 ms
Response time tA(line-earth) (Additional descriptions) ≤ 100 ns
Maximum continuous voltage UC (Additional descriptions) 15 V DC
Pulse reset time (line-earth) (Additional descriptions) ≤ 50 ms
Impulse durability (line-line) (Additional descriptions) C1 - 1 kV/500 A
Surge protection fault message (Additional descriptions) Optical, multi-stage
Impulse durability (line-earth) (Additional descriptions) C1 - 1 kV/500 A
Flammability rating according to UL 94 (Ambient conditions) V-0
Operating effective current ICat UC (Additional descriptions) ≤ 1 µA (in the signal circuit)
Voltage protection level Up(line-line) (Additional descriptions) ≤ 65 V (C1 - 1 kV/500 A)
Voltage protection level Up(line-earth) (Additional descriptions) ≤ 600 V (C1 - 1 kV/500 A)
Total discharge current Itotal(8/20) µs (Additional descriptions) 20 kA
Voltage protection level Upstatic (line-line) (Additional descriptions) ≤ 45 V (C1 - 1 kV/500 A)
Nominal discharge current In(8/20) µs (line-line) (Additional descriptions) 10 kA
Cut-off frequency fg (3 dB), sym. in 150 Ohm system (Additional descriptions) typ. 600 kHz
Nominal discharge current In(8/20) µs (line-earth) (Additional descriptions) 10 kA
Pulse discharge current Iimp(10/350) µs (line-earth) (Additional descriptions) 2.5 kA

Descrição do produto

More details
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top