Horário de atendimento: Segunda a sexta, das 9h às 18h.
PTFIX 6/18X2,5 BUWH - PTFIX 6/18X2,5 BUWH 1091673 PHOENIX CONTACT Block for distribution, Terminal base with power, The blocks can..
Em estoque Produto em alta

PTFIX 6/18X2,5 BUWH

PTFIX 6/18X2,5 BUWH 1091673 PHOENIX CONTACT Block for distribution, Terminal base with power, The blocks can..

$0.00 USD
3704 em estoque
Especificações principais
: For power distribution applications, IEC 60364-4-43:2008, as amended + Corrigendum Ott. 2008 (DIN VDE 0100-430:2010-10) section 433.2 ff!
note: The maximum load current of the individual connection points must not be exceeded.
Color: multicoloured
Depth: 21.7 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
For power distribution applications, IEC 60364-4-43:2008, as amended + Corrigendum Ott. 2008 (DIN VDE 0100-430:2010-10) section 433.2 ff!
note The maximum load current of the individual connection points must not be exceeded.
Color multicoloured
Depth 21.7 mm
width 56.5 mm
Result Test passed
height 28.6 mm
Feeding Yes
Spectrum Category 2 Electrical Life Check, Trolley Mounted
ASD Level 6.12 (m/s²)²/Hz
Frequency f1= 5 Hz up to f2= 250 Hz
Gauge Pad A3
Potential 1
Shock Form Semi-sinusoidal
Acceleration 3.12g
Product Type Distribution terminal
Mounting type Mounting on adapters for mounting on a support rail
Rated current 24 A
Article review 01
Number of rows 1
Open side wall no
Shock Duration 18 ms
Nominal voltage 450 V
Test Directions X, Y, and Z axis
AWG Sizing Section 14
Note for Operation The blocks can be bridged together over the conductor compartment, for suitable plug-in jumpers, see accessories
Test Specification DIN EN 50155 (VDE 0115-200):2008-03
Degree of pollution 3
Insulation material PA
Maximum load current 32 A (with a conductor cross-section of 4 mm²)
Overvoltage Category Iii
Nominal cross-section 2.5 mm²
Number of connections 19
Sizing Impulse Voltage 6 kV
Test duration per axle 5 h
Duration of application 30 s
Insulation Material Group The
Maximum cumulative current 57 A (with a conductor cross-section of 10 mm²)
Conductor cross-section AWG 26 ... 12 (converted according to IEC)
Support rail/fixing support NS 35/NS 15
Rigid conductor cross-section 0.14 mm² ... 4 mm²
Standard-compliant connection IEC 60998-2-2
Ambient temperature (mounting) -5 °C ... 70 °C
Number of connections per plan 19
Number of shocks per direction 3
Ambient temperature (operating) -60 °C ... 110 °C (Operating temperature range including self-heating, short-term maximum operating temperature cf. RTI Elec.)
Ambient Temperature (Activation) -5 °C ... 70 °C
Flexible conductor cross-section 0.14 mm² ... 2.5 mm²
Permissible humidity (operation) 20 % ... 90 %
NFPA 130 Fume Toxicity (SMP 800C) Exceeded
Solid conductor cross-section [AWG] 24 ... 12 (converted according to IEC)
Length of the section to be stripped 8 mm ... 10 mm
Cold static insulation material insert -60 °C
Flexible conductor cross-section [AWG] 26 ... 14 (converted according to IEC)
Ambient temperature (storage/transport) -25 °C ... 60 °C (for short duration, no longer than 24 h, -60 °C to +70 °C)
Combustibility class according to UL 94 V0
Permissible humidity (storage/transport) 30 % ... 70 %
Surface Flammability NFPA 130 (ASTM E 162) Exceeded
Maximum power dissipation under nominal conditions 0.77 W
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
NFPA 130 (ASTM E 662) Specific Optical Density of Fumes Exceeded
Flexible conductor cross-section (plastic lug and collar) 0.14 mm² ... 2.5 mm²
Heat development calorimetric cone NFPA 130 (ASTM E 1354) 28 MJ/kg
Insulation Material Relative Temperature Index (Elec., UL 746 B) 130 °C
Flexible conductor cross-section (cable lug without insulation collar) 0.14 mm² ... 2.5 mm²
Temperature index for insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
2 conductors of identical cross-section flexible with TWIN ferrule with plastic collar 0.5 mm² ... 1.5 mm²
Flexible conductor cross-section (2 conductors of identical cross-section with TWIN ferrule with plastic collar) 0.5 mm² ... 1.5 mm²

Descrição do produto

Distribution block, Base terminal with power, nominal voltage: 450 V, nominal current: 24 A, number of connections: 19, connection type: Push-in connection, Branch, section: 0.14 mm² - 4 mm², Push-in
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação