Parâmetro Valor
Machine building
Note The rated insulation voltage applies to insulated cable lugs acc. to DIN 46237:1970-07 with or without path extension and for uninsulated cable lugs acc. to DIN 46234:1980-03 with path extension.
Color gray (RAL 7042)
Width 10 mm
Height 66 mm
Result Test passed
output (Permanent)
General Note: the BE-RT... path extension is to be used for non-insulated cable lugs (see accessories).
Spectrum Service life test category 1, class B, body mounted
ASD level 1.857 (m/s²)²/Hz
Frequency f1= 5 Hz to f2= 150 Hz
Potentials 1
Bridge data 41 A / 6 mm²
Pulse shape Half-sine
Acceleration 0.8g
Product type Bolt connection terminal block
Screw thread M5
Torque range 2.5 Nm ... 3 Nm
Bolt diameter 5 mm
Cross section 0.5 mm² ... 6 mm²
Hole diameter 5.3 mm
Mounting type NS 35/7,5
Rated current 41 A
Rated voltage 550 V
Specification DIN EN 50155 (VDE 0115-200):2008-03
Identification  II 2 G  Ex eb IIC Gb
Number of rows 1
Product family RT
Shock duration 30 ms
End cover width 2.2 mm
List of bridges Plug-in bridge / FBS 2-8 / 3030284
Nominal current 41 A
Nominal voltage 1000 V
Open side panel Yes
Test directions X-, Y- and Z-axis
Article revision 09
Stripping length The stripping length depends on the specification provided by the cable lug manufacturer.
Time of exposure 30 s
Tightening torque 2.5 ... 3 Nm
Contact resistance 0.41 mΩ
Depth on NS 35/15 58.5 mm
Area of application Railway industry
Degree of pollution 3
Depth on NS 35/7,5 51 mm
Insulating material PA
Rated surge voltage 8 kV
Maximum load current 41 A (with 6 mm² conductor cross section)
Overvoltage category III
Nominal cross section 6 mm²
Number of connections 2
Test voltage setpoint 9.8 kV
Test duration per axis 5 h
Connection capacity AWG 26 ... 10
Cross section range AWG 20 ... 10 (converted acc. to IEC)
DIN rail/fixing support NS 35
Ex temperature increase 40 K (41 A at 6 mm²)
Rated cross section AWG 10
Ex-certified accessories 3049097 D-RT 3/5
Rated insulation voltage 500 V
for bridging with bridge 550 V
Connection capacity rigid 0.1 mm² ... 6 mm²
Insulating material group I
Operating temperature range -60 °C ... 110 °C
Connection capacity flexible 0.1 mm² ... 6 mm²
Ambient temperature (assembly) -5 °C ... 70 °C
Number of shocks per direction 3
Ambient temperature (actuation) -5 °C ... 70 °C
Ambient temperature (operation) -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Number of connections per level 2
Connection in acc. with standard IEC 60947-7-1
Permissible humidity (operation) 20 % ... 90 %
Requirement temperature-rise test Increase in temperature ≤ 45 K
Short-time withstand current 6 mm² 0.72 kA
- At cut-to-length bridging with cover 220 V
Flammability rating according to UL 94 V0
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Permissible humidity (storage/transport) 30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162) passed
Identification color of ring cable lugs : red 1 mm²
Identification color of ring cable lugs : blue 2.5 mm²
Static insulating material application in cold -60 °C
Maximum power dissipation for nominal condition 1.31 W
- At cut-to-length bridging with partition plate 550 V
Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
Identification color of ring cable lugs : yellow 6 mm²
- At bridging between non-adjacent terminal blocks 220 V
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C

Descrição do produto

Stud connection terminal, nominal voltage: 1000 V, nominal current: 41 A, number of connections: 2, connection type: Stud connection, Dimensioning section: 6 mm², mounting class: NS 35/7.5, NS 35/15,
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top