Horário de atendimento: Segunda a sexta, das 9h às 18h.
SACB-C-H180-4/ 8-5,0PUR SCO - SACB-C-H180-4/ 8-5,0PUR SCO 1516593 PHOENIX CONTACT Connector hood
Em estoque Produto em alta

SACB-C-H180-4/ 8-5,0PUR SCO

SACB-C-H180-4/ 8-5,0PUR SCO 1516593 PHOENIX CONTACT Connector hood

$62.90 USD
196 em estoque
Especificações principais
GTIN: 4017918967383
(Cable): For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey: 1516593
(General): -5 °C ... 80 °C (for flexible installation)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4017918967383
(Cable) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey 1516593
(General) -5 °C ... 80 °C (for flexible installation)
Catalog page Page 271 (C-2-2017)
Packing unit 1 pc
Country of origin PL (Poland)
China RoHS (Cable) Environmentally Friendly Use Period = 50
REACh SVHC (Cable) Lead 7439-92-1
Custom tariff number 85444290
(Insulation material) 1-4 / 5 (PE) = GN/YE
(Standards and Regulations) -5 °C ... 80 °C (cable, flexible installation)
Degree of protection (General) IP65
Rated voltage (Key Commercial Data) 120 V
Length of cable (Ambient conditions) 5 m
Weight per Piece (excluding packing) 699.900 g
Number of slots (Key Commercial Data) 4
Cable type (Standards and Regulations) PUR/PVC black
Connection method (Ambient conditions) Pluggable screw connection
Wire colors (Standards and Regulations) brown, blue, green/yellow, white, green, yellow, gray, gray/pink, red/blue, white/green, brown/green
Cable weight (Standards and Regulations) 122 kg/km
UL AWM style (Standards and Regulations) 20549
Ambient temperature (operation) (General) -30 °C ... 80 °C
Overall twist (Standards and Regulations) Wires twisted in layers
Total rated current (Key Commercial Data) 10 A
Bending radius (Standards and Regulations) 87 mm
AWG signal line (Standards and Regulations) 20
Traversing path (Standards and Regulations) 2 m
Traversing rate (Standards and Regulations) 2 m/s
AWG power supply (Standards and Regulations) 17
Flame resistance (Standards and Regulations) DIN EN 50265
Other resistance (Standards and Regulations) Highly resistant to acids, alkaline solutions and solvents
Resistance to oil (Standards and Regulations) according to VDE 0472 Part 803
Cable abbreviation (Standards and Regulations) LiYY11Y-HF
Conductor material (Standards and Regulations) Bare Cu litz wires
Special properties (Standards and Regulations) Silicone-free
Housing material (Master cable connection data) PBT
Test voltage, cable (Standards and Regulations) 2000 V
Connection in acc. with standard (Pin assignment) CUL
Tightening torque, union nut (Ambient conditions) 2.5 Nm
External sheath, color (Standards and Regulations) black RAL 9005
Inner sheath thickness (Standards and Regulations) ≥ 0.15 mm
Material, inner sheath (Standards and Regulations) PVC
Nominal voltage, cable (Standards and Regulations) 300 V
Outer sheath thickness (Standards and Regulations) ≥ 0.38 mm
Outer sheath, material (Standards and Regulations) PUR
Conductor cross section (Standards and Regulations) 8x 0.5 mm² (Signal line)
Tightening torque, cover screw (Ambient conditions) 0.35 Nm
Number of bending cycles (Standards and Regulations) 1500000
Cable type (abbreviation) (Standards and Regulations) PUR
External cable diameter D (Standards and Regulations) 8.7 mm ±0.2 mm
Sensor/actuator connection system (Key Commercial Data) M12-SPEEDCON-socket
Current carrying capacity per slot (Key Commercial Data) 4 A
Material conductor insulation (Standards and Regulations) PVC
Ambient temperature (operation) (Standards and Regulations) -40 °C ... 90 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations) 28x 0.15 mm
Core diameter including insulation (Standards and Regulations) 1.5 mm ±0.1 mm (Signal line)
Current carrying capacity per I/O signal (Key Commercial Data) 2 A
Slot/position = Wire color or connection (Insulation material) 1 / 4 (A) = WH
Conductor structure, voltage supply (Standards and Regulations) 56x 0.15 mm
Material of contact, master cable side (Master cable connection data) CU alloy
Minimum bending radius, fixed installation (Standards and Regulations) 7.5 x D
Minimum bending radius, flexible installation (Standards and Regulations) 10 x D
Material of contact surface, master cable side (Master cable connection data) Gold-plated
Material of the contact carrier on the master cable side (Master cable connection data) PA

Descrição do produto

Connection cover, application: sensor/actuator box, connection type: SPEEDCON M12 Metal / QUICKON female connector, number of plug-in stations: 4, occupation of plug-in stations: Double, status indica
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação