Item: Specifications
PFHD: 1.66 × 10-10(Note:Probability of dangerous failure per hour)
MTTFD: 100 years or more(Note:Mean time to dangerous failure (in years))
Weight: Net weight: 250 g approx.
Informações do fornecedor
PANASONIC
PANASONIC
Produtos: 4316
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Item Specifications
PFHD 1.66 × 10-10(Note:Probability of dangerous failure per hour)
MTTFD 100 years or more(Note:Mean time to dangerous failure (in years))
Weight Net weight: 250 g approx.
Details Applicantion expansion unit for the SF4B series
Product Exclusive Control Unit for Safety Light Curtain
Material Enclosure: ABS
Part Number SF-C14EX
Product name Exclusive Control Unit for Safety Light Curtain SF-C10
Power voltage 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Product Number SF-C14EX
Ambient humidity 30 to 85 % RH, Storage: 30 to 95 % RH
Control category ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards
Shock resistance 30 G acceleration in X, Y and Z directions three times each
Muting lamp output Applicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit)
Ambient temperature -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158 ℉
Connection terminal Detachable spring-cage terminal
Current consumption 0.2 A or less (Excluding Safety light curtain and other external connecting device)
Vibration resistance 10 to 55 Hz frequency, 0.35 mm0.014 indouble amplitude in X, Y and Z directions for two hours each
Insulation resistance 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Applicable standards:Japan JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4, PLe)
CE marking directive compliance Machinery Directive, EMC Directive, RoHS Directive
Applicable standards:Europe (EU) EN 55011, EN ISO 13849-1 (Category 4, PLe)
Connectable safety light curtains SF4B / SF4B-Gseries(Note:The handy-controllerSFB-HC(optional) cannot be used withSF-C14EX-01.)
Applicable standards:North America ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2)
Muting lamp output:Protection circuit Incorporated
Applicable standards:International standard IEC 61496-1 (Type 4), IEC 61496 (Type 4),ISO 13849-1 (Category 4, PLe)
Environmental resistance:Degree of protection Enclosure: IP40Terminal: IP20
Environmental resistance:Dielectric strength voltage 1,000 V AC for one min. between all supply terminals connected together and enclosure
Safety outputs(Safety output 1, Safety output 2, Safety output 3) PNP open-collector transistor 2 outputs × 3 or NPN open-collector transistor 2 outputs × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 200 mA・Applied voltage: same as supply voltage(between the safety output and +V)・Residual voltage: 2 V or less (at 200 mA source current)<When NPN output is selected>・Maximum sink current: 200 mA・Applied voltage: same as supply voltage(between the safety output and 0 V)・Residual voltage: 2 V or less (at 200 mA sink current)
Safety outputs(Safety output 1, Safety output 2, Safety output 3):Response time OFF response: 14 ms or less (Safety output 1 and 2: including the response time of the Safety light curtain)ON response: 90 ms or less (auto-reset) / 140 ms or less (manual reset) (Note)(Note) The auto-reset cannot be used with safety output 3.
Auxiliary outputs(Auxiliary output 1, Auxiliary output 2, Auxiliary output 3, Auxiliary output 4) PNP open-collector transistor × 3 or NPN open-collector transistor × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and +V)・Residual voltage: 2 V or less (at 60 mA source current)<When NPN output is selected>・Maximum sink current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and 0 V)・Residual voltage: 2 V or less (at 60 mA sink current)
Safety outputs(Safety output 1, Safety output 2, Safety output 3):Operation mode(Output operation) Safety output 1: ON when the safety light curtain is in light receiving condition, OFF when the safety light curtain is in light interrupted condition (Note 3)Safety output 2: ON when the safety light curtain is in light receiving condition or the muting function is validOFF when the safety light curtain is in light interrupted condition and the muting function is invalid (Note 3)Safety output 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid
Safety outputs(Safety output 1, Safety output 2, Safety output 3):Protection circuit(Short-circuit protection) Incorporated
Auxiliary outputs(Auxiliary output 1, Auxiliary output 2, Auxiliary output 3, Auxiliary output 4):Operation mode(Output operation) Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is validAuxiliary output 2: ON when the override function is invalid, OFF when the override function is validAuxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is errorAuxiliary output 4: ON when the light curtain is in light interrupted condition, OFF when the light curtain is in light receiving condition(Note:The auxiliary output incorporated in theSF4Bseries is output.)
Auxiliary outputs(Auxiliary output 1, Auxiliary output 2, Auxiliary output 3, Auxiliary output 4):Protection circuit(Short-circuit protection) Incorporated

Descrição do produto

SF-C14EX_Exclusive Control Unit for Safety Light Curtain_Exclusive Control Unit for Safety Light Curtain SF-C10_Applicantion expansion unit for the SF4B series
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top