Horário de atendimento: Segunda a sexta, das 9h às 18h.
SOL-SC-1ST-0-DC-1MPPT-1004 - SOL-SC-1ST-0-DC-1MPPT-1004 1094675 PHOENIX CONTACT String combiner box for photovoltaic systems up to 1000 V..
Em estoque Produto em alta

SOL-SC-1ST-0-DC-1MPPT-1004

SOL-SC-1ST-0-DC-1MPPT-1004 1094675 PHOENIX CONTACT String combiner box for photovoltaic systems up to 1000 V..

$0.00 USD
3674 em estoque
Especificações principais
GTIN: 4055626921129
Orderkey: 1094675
(Drawings):
Packing unit: 1
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4055626921129
Orderkey 1094675
(Drawings)
Packing unit 1
ETIM 4.0 (eCl@ss) EC000816
ETIM 5.0 (eCl@ss) EC000268
ETIM 6.0 (eCl@ss) EC000268
ETIM 7.0 (eCl@ss) EC000268
Custom tariff number 85363030
System voltage (Drawings) 1000 V DC (Umax)
Number of outputs (Drawings) 1 (per MPP tracker)
eCl@ss 5.1 (Classifications) 27371890
eCl@ss 7.0 (Classifications) 27142422
eCl@ss 8.0 (Classifications) 27142422
eCl@ss 9.0 (Classifications) 27142422
Protection class (Cable entry) II
eCl@ss 10.0.1 (Classifications) 27142422
Material cover/door (Cable entry) Polycarbonate (transparent)
Degree of protection (Cable entry) IP65
Number of string inputs (Drawings) 1
Current per string (max.) (Drawings) 40 A (Imax)
Protection level Up (System parameter) ≤ 3.5 kV
Type of cable entry (Safety equipment) SUNCLIX
Sealing area grounding (Safety equipment) 6 mm ... 12 mm (2x)
Surge protective device (System parameter) T1 / T2
Number of supported MPP trackers (Drawings) 1
Ambient temperature (operation) (Dimensions) -20 °C ... 55 °C
Cable cross section output (Safety equipment) 6 mm² ... 16 mm²
Cable cross section grounding (Safety equipment) 16 mm² (2x)
Cable cross section string input (Safety equipment) 6 mm² ... 16 mm²
Outer dimensions: width, height, depth (General data) 130 mm x 180 mm x 111 mm (Housing dimensions)
Schematic diagramConnection of the PV string (Drawings)
Connection diagramSchematic application drawing (Drawings)
Total discharge current Itotal(8/20) µs (System parameter) 40 kA
Total discharge current Itotal(10/350) µs (System parameter) 5 kA
Schematic diagramConnection of the protective grounding conductor (Drawings)

Descrição do produto

Generator connection box for photovoltaic installations up to 1000 V DC for 1x 1 string connection. With surge protection and SUNCLIX DC connector for the input and output side.
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Detalhes técnicos

Connection diagramSchematic application drawing

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top