Especificações principais
GTIN: 4017918900571
Orderkey: 3036550
Catalog page: Page 177 (C-1-2017)
Packing unit: 50 pc
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4017918900571
Orderkey 3036550
Catalog page Page 177 (C-1-2017)
Packing unit 50 pc
Width (General) 6.2 mm
Length (General) 61.5 mm
Country of origin TR (Turkey)
(Connection data) IEC 60947-7-3
Custom tariff number 85369095
(Key Commercial Data) max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit)
Height NS 35/15 (General) 70 mm
Fuse (Key Commercial Data) G / 5 x 20
Height NS 35/7,5 (General) 62.5 mm
Color (Key Commercial Data) black
Stripping length (Dimensions) 8 mm ... 10 mm
Connection method (Dimensions) Spring-cage connection
Fuse type (Key Commercial Data) Glass / ceramics / ...
Weight per Piece (excluding packing) 15.310 g
Open side panel (Key Commercial Data) No
Internal cylindrical gage (Dimensions) A4
Number of levels (Key Commercial Data) 1
LED current range (Key Commercial Data) 0.4 mA ... 0.86 mA
LED voltage range (Key Commercial Data) 30 V AC/DC ... 60 V AC/DC
Nominal current IN (Key Commercial Data) 6.3 A
Nominal voltage UN (Key Commercial Data) 60 V
Degree of pollution (Key Commercial Data) 3
Insulating material (Key Commercial Data) PA
Rated surge voltage (Key Commercial Data) 4 kV
Maximum load current (Key Commercial Data) 6.3 A (the current is determined by the fuse used)
Overvoltage category (Key Commercial Data) III
Nominal cross section (Key Commercial Data) 4 mm²
Number of connections (Key Commercial Data) 2
Conductor cross section AWG max. (Dimensions) 10
Conductor cross section AWG min. (Dimensions) 28
Conductor cross section solid max. (Dimensions) 6 mm²
Conductor cross section solid min. (Dimensions) 0.08 mm²
Insulating material group (Key Commercial Data) I
Maximum power dissipation (Key Commercial Data) max. 1.6 W (With single arrangement of the fuse terminal block in the event of overload)
Conductor cross section flexible max. (Dimensions) 4 mm²
Conductor cross section flexible min. (Dimensions) 0.08 mm²
Connection in acc. with standard (Connection data) CSA
NF F16-101, NF F10-102 Class F (Key Commercial Data) 2
NF F16-101, NF F10-102 Class I (Key Commercial Data) 2
Connection in acc. with standard (Key Commercial Data) IEC 60947-7-3
Oxygen index (DIN EN ISO 4589-2) (Key Commercial Data) >32 %
Flammability rating according to UL 94 (Connection data) V0
Flame test method (DIN EN 60695-11-10) (Key Commercial Data) V0
Flammability rating according to UL 94 (Key Commercial Data) V0
Smoke gas toxicity NFPA 130 (SMP 800C) (Key Commercial Data) passed
Surface flammability NFPA 130 (ASTM E 162) (Key Commercial Data) passed
Static insulating material application in cold (Key Commercial Data) -60 °C
Behavior in fire for rail vehicles (DIN 5510-2) (Key Commercial Data) Test passed
Maximum power dissipation for nominal condition (Key Commercial Data) 1.6 W
Calorimetric heat release NFPA 130 (ASTM E 1354) (Key Commercial Data) 28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Connection data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Key Commercial Data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Key Commercial Data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Key Commercial Data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Key Commercial Data) HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) (Key Commercial Data) passed
Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions) 4 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions) 0.14 mm²
Relative insulation material temperature index (Elec., UL 746 B) (Key Commercial Data) 130 °C
Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions) 4 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions) 0.14 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Key Commercial Data) 130 °C
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions) 1 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (Dimensions) 0.5 mm²

Descrição do produto

Fuse terminal block, fuse type: Glass/ceramic/..., fuse type: G/5 x 20, nominal voltage: 60 V, nominal current: 6.3 A, connection type: Spring connection, 1st floor, Sizing cross-section: 1 mm², cross
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top