Horário de atendimento: Segunda a sexta, das 9h às 18h.
TAE-TRAB FM-NFN-AP - TAE-TRAB FM-NFN-AP 2749628 PHOENIX CONTACT Surge protection device
Em estoque Produto em alta

TAE-TRAB FM-NFN-AP

TAE-TRAB FM-NFN-AP 2749628 PHOENIX CONTACT Surge protection device

$0.00 USD
4051 em estoque
Especificações principais
GTIN: 4017918108199
Orderkey: 2749628
(General): D1 - 2.5 kA
Catalog page: Page 165 (C-4-2017)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4017918108199
Orderkey 2749628
(General) D1 - 2.5 kA
Catalog page Page 165 (C-4-2017)
Packing unit 1 pc
Country of origin DE (Germany)
Custom tariff number 85363010
(Ambient conditions) IEC 60664-1
Rated current (General) 450 mA (≤ 40°C)
Type (Ambient conditions) Socket for surface mounting
Color (Ambient conditions) cream white
Depth (Key Commercial Data) 80 mm
Width (Key Commercial Data) 65 mm
Height (Key Commercial Data) 27 mm
Nominal voltage UN (General) 60 V DC
Capacity (line-line) (General) typ. 200 pF (f = 1 MHz / VR = 0 V)
Residual current IPE (General) ≤ 6 µA
Resistance in series (General) 2.2 Ω 10 %
Capacity (line-earth) (General) typ. 15 pF (f = 1 MHz / VR = 0 V)
VDE requirement class (General) B2
Degree of protection (Dimensions) IP20
IEC test classification (General) B2
Screw thread (Protective circuit) M3
Mounting type (Ambient conditions) Surface/Wall mounting
Stripping length (Connection data) 6 mm
Connection method (Connection data) Screw terminal block
(Connection, equipotential bonding) IEC 61643-21 2000
Input attenuation aE, sym. (General) 0.3 dB (≤ 1 MHz / 150 Ω)
Weight per Piece (excluding packing) 79.600 g
Housing material (Ambient conditions) ABS
Input attenuation aE, asym. (General) 0.3 dB (≤ 400 kHz / 600 Ω)
Response time tA(line-line) (General) ≤ 1 ns
Stripping length (Protective circuit) 6 mm
Connection method (Protective circuit) Screw connection & TAE 6
Response time tA(line-earth) (General) ≤ 100 ns
Tightening torque (Protective circuit) 0.5 Nm
Maximum continuous voltage UC (General) 185 V DC
Direction of action (Ambient conditions) Line-Line & Line-Earth Ground
Impulse durability (line-line) (General) C2 - 10 kV/5 kA
Surge protection fault message (General) none
Tightening torque, min (Connection data) 0.5 Nm
Connection method IN (Protective circuit) Screw terminal blocks
Impulse durability (line-earth) (General) C2 - 10 kV/5 kA
Connection method OUT (Protective circuit) 3x TAE-NFN
Connection technology (Protective circuit) Screw connection
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
Operating effective current ICat UC (General) ≤ 10 µA
Short-circuit current self-quenching (General) 150 mA
Conductor cross section AWG (Protective circuit) 26 ... 16
For country-specific use in (Ambient conditions) D
Voltage protection level Up(line-line) (General) ≤ 250 V (C2 - 10 kV / 5 kA)
Voltage protection level Up(line-earth) (General) ≤ 500 V (C2 - 10 kV / 5 kA)
Conductor cross section AWG max. (Connection data) 16
Conductor cross section AWG min. (Connection data) 26
Conductor cross section solid (Protective circuit) 0.14 mm² ... 1.5 mm²
Total discharge current Itotal(8/20) µs (General) 10 kA
Conductor cross section solid max. (Connection data) 1.5 mm²
Conductor cross section solid min. (Connection data) 0.14 mm²
Total discharge current Itotal(10/350) µs (General) 5 kA
Conductor cross section flexible (Protective circuit) 0.14 mm² ... 1.5 mm²
Conductor cross section flexible max. (Connection data) 1.5 mm²
Conductor cross section flexible min. (Connection data) 0.14 mm²
Standards/regulations (Connection, equipotential bonding) IEC 61643-21
Alternating current carrying capacity (line-earth) (General) 5 A - 1 s
Nominal discharge current In(8/20) µs (line-line) (General) 5 kA
Nominal pulse current Ian (10/700) µs (line-line) (General) 150 A
Standards/specifications (Connection, equipotential bonding) DIN EN 61643-21 2002
Cut-off frequency fg (3 dB), sym. in 150 Ohm system (General) typ. 8 MHz
Cut-off frequency fg (3 dB), sym. in 600 Ohm system (General) typ. 2 MHz
Nominal discharge current In(8/20) µs (line-earth) (General) 5 kA
Nominal pulse current Ian (10/1000) µs (line-line) (General) 100 A
Nominal pulse current Ian (10/700) µs (line-earth) (General) 150 A
Nominal pulse current Ian (10/1000) µs (line-earth) (General) 100 A
Output voltage limitation at 1 kV/µs (line-line) spike (General) ≤ 250 V
Output voltage limitation at 1 kV/µs (line-earth) spike (General) ≤ 450 V
Output voltage limitation at 1 kV/µs (line-line) static (General) ≤ 250 V
Max. discharge current Imax(8/20) µs maximum (line-line) (General) 5 kA
Output voltage limitation at 1 kV/µs (line-earth) static (General) ≤ 450 V
Standards for cearances and creepage distances (Ambient conditions) VDE 0110-1
Max. discharge current Imax(8/20) µs maximum (line-earth) (General) 5 kA

Descrição do produto

Spray-protected TAE (NFN) connection box with surge protection for analogue and digital telecommunication interfaces (VDSL up to 50 MBit/s, short distances (< 300 m) up to 100 MBit/s)
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top