Horário de atendimento: Segunda a sexta, das 9h às 18h.
TRIO-PS-IP67/3AC/24DC/20 - TRIO-PS-IP67/3AC/24DC/20 1039829 PHOENIX CONTACT TRIO POWER primary-switched power supply in IP67 die-cast h..
Em estoque Produto em alta

TRIO-PS-IP67/3AC/24DC/20

TRIO-PS-IP67/3AC/24DC/20 1039829 PHOENIX CONTACT TRIO POWER primary-switched power supply in IP67 die-cast h..

$0.00 USD
4113 em estoque
Especificações principais
GTIN: 4055626595795
Orderkey: 1039829
(Drawings):
(Standards): 2 kV (Test Level 1 - asymmetrical)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4055626595795
Orderkey 1039829
(Drawings)
(Standards) 2 kV (Test Level 1 - asymmetrical)
Catalog page Page 265 (C-4-2019)
Packing unit 1
(Input data) < 44 W (480 V AC)
(Output data) > 230000 h (60 °C)
Coding (General) S-coded
Depth (Drawings) 120 mm
Width (Drawings) 151 mm
ETIM 5.0 (eCl@ss) EC002540
ETIM 6.0 (eCl@ss) EC002540
ETIM 7.0 (eCl@ss) EC002540
Height (Drawings) 304 mm
Input (Standards) 2 kV (Test Level 3 - symmetrical)
Output (Standards) 1 kV (Test Level 2 - symmetrical)
Signal (Standards) 1 kV (Test Level 1 - asymmetrical)
Flicker (Standards) EN 61000-3-3
Voltage (Standards) 400 V AC
Comments (Standards) Criterion A
Custom tariff number 85044030
(Ambient conditions) typ. 20 ms (500 V AC)
Derating (Input data) > 60 °C ... 70 °C (2.5%/K)
Frequency (Standards) 50 Hz
REACh SVHC (EMC data) Lead 7439-92-1
Criterion A (Standards) Normal operating behavior within the specified limits.
Criterion B (Standards) Temporary impairment to operational behavior that is corrected by the device itself.
Criterion C (Standards) Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
Voltage dip (Standards) 0 %
Efficiency (Output data) 93 % (400 V AC)
Net weight (Output data) 3.7 kg
Voltage dips (Standards) EN 61000-4-11
Output power (Input data) 480 W
Type of locking (General) M12 screw locking
Noise emission (Standards) EN 55016
Additional text (Standards) Test Level 2
Climatic class (Dimensions) 3K3 (in acc. with EN 60721)
Connection method (General) Circular connector
Frequency range (Standards) 0.15 MHz ... 80 MHz
Discharge in air (Standards) 8 kV (Test Level 4)
Residual ripple (Input data) ≤ 20 mVPP
eCl@ss 8.0 (Classifications) 27049002
eCl@ss 9.0 (Classifications) 27040701
Contact discharge (Standards) 6 kV (Test Level 4)
Number of periods (Standards) 1 period
Number of positions (General) 4
Control deviation (Input data) < 1 % (change in load, static 10 % ... 90 %)
Protection class (Output data) I
Coding (Connection data, input) N-coded
Input fuse (Ambient conditions) 3.15 A (internal (device protection), slow-blow)
Test field strength (Standards) 10 V/m (Test Level 3)
Coding (Connection data, output) A-coded
Degree of pollution (Dimensions) 4
Installation height (Dimensions) ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
Degree of protection (Dimensions) IP67
Low Voltage Directive (Standards) Conformance with Low Voltage Directive 2014/35/EC
Conducted interference (Standards) EN 61000-4-6
Degree of protection (Output data) IP67
Typical response time (Input data) < 1 s
Assembly instructions (Output data) Alignable: 20 mm horizontally, 50 mm vertically above, 100 mm vertically below
Electrostatic discharge (Standards) EN 61000-4-2
Fast transients (burst) (Standards) EN 61000-4-4
Inrush current (Ambient conditions) typ. 22 A (at 25 °C)
Nominal output voltage (Input data) 24 V DC ±1 %
Conducted noise emission (Standards) EN 55016
Electromagnetic HF field (Standards) EN 61000-4-3
Surge voltage load (surge) (Standards) EN 61000-4-5
AC frequency range (Ambient conditions) 50 Hz ... 60 Hz
Dynamic Boost (IDyn.Boost) (Input data) 30 A (5 s)
Type of protection (Ambient conditions) Transient surge protection
Current consumption (Ambient conditions) 3x 1.2 A (400 V AC)
Input voltage range (Ambient conditions) 3x 400 V AC ... 500 V AC -20 % ....+15 %
MTBF (IEC 61709, SN 29500) (Output data) > 1500000 h (25 °C)
Nominal output current (IN) (Input data) 20 A
Type of locking (Connection data, input) M17 standard and SPEEDCON locking
Electromagnetic compatibility (Standards) Conformance with EMC Directive 2014/30/EU
Mains buffering time (Ambient conditions) typ. 10 ms (400 V AC)
Power loss nominal load max. (Input data) < 44 W (400 V AC)
Type of locking (Connection data, output) SPEEDCON M12
Connection method (Connection data, input) Circular connector
Connection method (Connection data, output) Circular connector
Ambient temperature (operation) (Dimensions) -25 °C ... 85 °C (Derating > 60 °C (3 AC): 2,5 %/K / > 50 °C (2 AC): 2,5 %/K)
Discharge current to PE (Ambient conditions) < 3.5 mA
Number of positions (Connection data, input) 4
Insulation voltage input/output (Output data) 4 kV AC (type test)
Number of positions (Connection data, output) 5
Nominal power consumption (Ambient conditions) 39 W
Nominal input voltage range (Ambient conditions) 3x 400 V AC ... 500 V AC
Protective circuit/component (Ambient conditions) Varistor
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 85 °C
Ambient temperature (start-up type tested) (Dimensions) -40 °C
Standard - Safe isolation (Connection data for signaling) DIN VDE 0100-410
Max. permissible relative humidity (operation) (Dimensions) ≤ 95 % (at 25 °C, non-condensing)
Maximum power dissipation in no-load condition (Input data) < 2 W (400 V AC)
Standard - Electrical safety (Connection data for signaling) IEC 61010-2-201 (SELV)
Recommended breaker for input protection (Ambient conditions) 6 A ... 16 A (Characteristics B, C, D, K)
Protection against overvoltage at the output (OVP) (Input data) ≤ 30 V DC
Standard – Safety extra-low voltage (Connection data for signaling) EN 60204-1 (PELV)
Standard – Limitation of mains harmonic currents (Connection data for signaling) EN 61000-3-2

Descrição do produto

TRIO POWER primary switching power supply in IP67 die-cast housing, input: three-phase, output: 24 V DC/20 A
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Detalhes técnicos

Block diagram

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top