Horário de atendimento: Segunda a sexta, das 9h às 18h.
TTC-6P-2X1-M-EX-24DC-UT-I - TTC-6P-2X1-M-EX-24DC-UT-I 2906825 PHOENIX CONTACT Surge protection, consisting of protective plug and base e..
Em estoque Produto em alta

TTC-6P-2X1-M-EX-24DC-UT-I

TTC-6P-2X1-M-EX-24DC-UT-I 2906825 PHOENIX CONTACT Surge protection, consisting of protective plug and base e..

$0.00 USD
3257 em estoque
Especificações principais
GTIN: 4055626135878
Orderkey: 2906825
(General): D1 - 500 A
(Drawings):
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4055626135878
Orderkey 2906825
(General) D1 - 500 A
(Drawings)
Catalog page Page 157 (C-4-2019)
Packing unit 1 pc
Depth (Drawings) 100 mm (incl. DIN rail 7.5 mm)
UNSPSC 11 (ETIM) 39121610
Width (Drawings) 6.2 mm +0.1 mm
Country of origin DE (Germany)
ETIM 3.0 (eCl@ss) EC000943
ETIM 4.0 (eCl@ss) EC000943
ETIM 5.0 (eCl@ss) EC000943
ETIM 6.0 (eCl@ss) EC000943
ETIM 7.0 (eCl@ss) EC000943
Height (Drawings) 105.8 mm
(Connection data) IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
Diagram (Drawings)
UNSPSC 13.2 (ETIM) 39121620
UNSPSC 18.0 (ETIM) 39121620
UNSPSC 19.0 (ETIM) 39121620
UNSPSC 20.0 (ETIM) 39121620
UNSPSC 21.0 (ETIM) 39121620
UNSPSC 6.01 (ETIM) 30212010
UNSPSC 12.01 (ETIM) 39121610
Custom tariff number 85363010
Pictogram (Drawings)
UNSPSC 7.0901 (ETIM) 39121610
Altitude (Dimensions) ≤ 2000 m (amsl (above mean sea level))
Rated current (General) 600 mA (40 °C)
UL, USA/Canada (General) Class I, Div. 2, Groups A, B, C, D T4A
(Conformity / approvals) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Type (Ambient conditions) DIN rail module, two-section, divisible
Color (Ambient conditions) sky blue RAL 5015
(Standards and Regulations) -40 °C ... 50 °C (T4 / 135 °C)
Nominal voltage UN (General) 24 V DC
eCl@ss 4.0 (Classifications) 27140201
eCl@ss 4.1 (Classifications) 27130801
eCl@ss 5.0 (Classifications) 27130801
eCl@ss 5.1 (Classifications) 27130801
eCl@ss 6.0 (Classifications) 27130800
eCl@ss 7.0 (Classifications) 27130807
eCl@ss 8.0 (Classifications) 27130807
eCl@ss 9.0 (Classifications) 27130807
Resistance per path (General) 1.65 Ω ±20 %
Residual current IPE (General) ≤ 10 µA
Capacity (line-earth) (General) typ. 2.2 nF
Degree of protection (Dimensions) IP20
IEC test classification (General) C1
Screw thread (Protective circuit) M3
Mounting type (Ambient conditions) DIN rail: TH 35 - 7.5 mm
China RoHS (Conformity / approvals) Environmentally Friendly Use Period = 50
REACh SVHC (Conformity / approvals) Lead 7439-92-1
Max. required back-up fuse (General) 630 mA (FF)
Weight per Piece (excluding packing) 40.000 g
Housing material (Ambient conditions) PBT
Input attenuation aE, asym. (General) typ. 0.3 dB (≤ 270 kHz/150 Ω)
Stripping length (Protective circuit) 8 mm
Connection method (Protective circuit) Screw connection
Response time tA(line-earth) (General) ≤ 1 ns
Tightening torque (Protective circuit) 0.5 Nm ... 0.6 Nm
Maximum continuous voltage UC (General) 30 V DC
Pulse reset time (line-earth) (General) ≤ 300 ms
Direction of action (Ambient conditions) Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Surge protection fault message (General) optical
Impulse durability (line-earth) (General) C1 - 1 kV / 500 A
Standards/specifications (Connection data) EN 60079-0 2012 + A11:2013
Ambient temperature (operation) (Dimensions) -40 °C ... 85 °C
Operating effective current ICat UC (General) ≤ 5 µA
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Conductor cross section AWG (Protective circuit) 24 ... 12
Max. input current Ii (Standards and Regulations) 400 mA (T4 / ≤ 50 °C)
Max. input voltage Ui (Standards and Regulations) 30 V DC
Voltage protection level Up(line-earth) (General) ≤ 140 V (C1 - 1 kV/500 A)
Conductor cross section solid (Protective circuit) 0.2 mm² ... 4 mm²
Total discharge current Itotal(8/20) µs (General) 10 kA
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 85 °C
Conductor cross section flexible (Protective circuit) 0.2 mm² ... 2.5 mm²
Max. internal inductance Li (Standards and Regulations) negligible
Maximum inner capacitance Ci (Standards and Regulations) negligible
Voltage protection level Upstatic (line-earth) (General) ≤ 55 V (C1 - 1 kV/500 A)
Ambient temperature (operation) (Standards and Regulations) -40 °C ... 35 °C (T6 / 85 °C)
Flammability rating according to UL 94 (Ambient conditions) V-0
Nominal discharge current In(8/20) µs (line-earth) (General) 5 kA
Pulse discharge current Iimp(10/350) µs (line-earth) (General) 0.5 kA
Cut-off frequency fg (3 dB), asym. (PE) in 150 Ohm system (General) typ. 960 kHz

Descrição do produto

More details
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Detalhes técnicos

Diagram

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top