Item: Specifications
Cable: 0.2 mm23-core heat resistant cabtyre cable 2 m3.562 ftlong
Remark: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃+73.4 ℉.The sensor head can be used independently.Oil is used in the factory inspection process for models DPH-L114 and DPH-L154. There may be some residual oil inside the pressure port.
Weight: Net weight : 100 g approx., Gross weight : 150 g approx.
Informações do fornecedor
PANASONIC
PANASONIC
Produtos: 4316
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Item Specifications
Cable 0.2 mm23-core heat resistant cabtyre cable 2 m3.562 ftlong
Remark Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃+73.4 ℉.The sensor head can be used independently.Oil is used in the factory inspection process for models DPH-L114 and DPH-L154. There may be some residual oil inside the pressure port.
Weight Net weight : 100 g approx., Gross weight : 150 g approx.
Details Sensor head
Product Head-separated Dual display Digital Pressure Sensor [For gas & liquid]
Material Diaphragm : Stainless steel (SUS603), Pressure port : Stainless steel (SUS304), Throttle : Stainless steel (SUSXM7)
Protection IP67 (IEC)
Accessories Connector (e-CON) : 1 pc.
Part Number DPH-L114
Product name Head-separated Dual display Digital Pressure Sensor [For gas & liquid] DPC-L100 / DPH-L100
Pressure port R1/4 male thread (throttle embeded)
Response time 1 ms or less
Product Number DPH-L114
Supply voltage 9 to 36 V DC[9 to 32 V DC when using the attached connector (e-CON)]
Cable extension Extension up to total 10 m32.808 ftis possible with 0.2 mm2, or more, cable.
Ambient humidity 35 to 85 % RH, Storage : 35 to 85 % RH
Applicable fluid Gases and fluids that do not corrode stainless steel SUS630, SUS304, or SUSXM7
Grounding method Capacitor earth (Enclosure-supply terminal)
Shock resistance 1,000 m/s2acceleration in X, Y and Z directions three times each
Type of pressure Sealed gauge pressure(Note): The sensor's internal mechanism is sealed based on an air pressure of 1,013 hPa.
Connecting method Connector
Ambient temperature -20 to +80 ℃ (Pressure port: -20 to +125 ℃\n-4 to +257 ℉, No dew condensation or icing allowed),\n Storage: -30 to +100 ℃-22 to +212 ℉\n[e-CON connector (accesory):-20 to +75 ℃\n-4 to +167 ℉\n(Storage: -30 to +75 ℃-22 to +167 ℉)]
Current consumption 20 mA or less
Rated pressure range 0 to +10 MPa
Vibration resistance 10 to 2,000 Hz frequency, acceleration 200 m/s2, in X direction for four hours, in Y and Z directions for two hours each(Note): The X, Y, and Z directions are defined as follows :
Analog voltage output Output voltage: 1 to 5 V DC (over rated pressure range)\n Accuracy: ±1.0 % F.S. (at 23 ±2 ℃+73.4 ±35 ℉)\n ±2.0 % F.S. (at -20 to 125 ℃-4 to +257 ℉)\n (including linearity, hysteresis and repeatability)
Insulation resistance 100 MΩ, or more, with 50 V DC megger between all supply terminals connected together and enclosure
Applicable regulations CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Medium temperature range -20 to +125 ℃-4 to +257 ℉
Voltage withstandability 150 V AC for one min. between all supply terminals connected together and enclosure
Pressure withstandability 20 MPa

Descrição do produto

Sensor head, positive pressure. 0 to 10MPa. R1/4 male pressure port.
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top