Especificações principais
Item: Specifications
Cable: 0.2 mm24-core cabtyre cable, 2 m6.562 ftlong
Remark: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23℃+73.4℉.
Weight: Net weight: 55 g approx., Gross weight: 80 g approx.
Informações do fornecedor
PANASONIC
PANASONIC
Produtos: 4316
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Item Specifications
Cable 0.2 mm24-core cabtyre cable, 2 m6.562 ftlong
Remark Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23℃+73.4℉.
Weight Net weight: 55 g approx., Gross weight: 80 g approx.
Material Enclosure, Case cover: Polycarbonate, Switch: Polyacetal
Protection IP40 (IEC)
Part Number FX-551L3-P-C2
Product name Digital Fiber Sensor FX-550L
Response time STD: 250 μs or less, LONG: 2 ms or less, U-LG: 4 ms or less, HYPR: 24 ms or less, selectable
Product Number FX-551L3-P-C2
Supply voltage 12 to 24 V DC+10-15% Ripple P-P 10 % or less
Timer function Incorporated with variable OFF-delay / ON-delay / One-shot, switchable either effective or ineffective
Cable extension Extension up to total 20 m65.617 ftis possible with 0.3 mm2, or more, cable.(Condition of CE compliance: less tan 20 m65.617 ft) (however, supply voltage 12 V DC or more)
Shock resistance 98 m/s2acceleration (10 G approx.) in X, Y and Z directions five times each
Power consumption Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage)ECO mode: 720 mW or less (current consumption 30 mA or less at 24 V supply voltage)
Ambient temperature -10 to +55℃+14 to +131℉(If 4 to 7 units are mounted in cascade: -10 to +50℃+14 to +122℉or if 8 to 16 units are mounted in cascade: -10 to +45℃+14 to +113℉) (No dew condensation or icing allowed), Storage: -20 to +70℃-4 to +158℉
Control output (DO) PNP open-collector transistor• Maximum source current: 50 mA• Applied voltage: 30 V DC or less (between output and +V)• Residual voltage: 2 V or less (Note) (at maximum source current)(Note:)In case of using the cable (cable length 2 m6.562 ft).
Sensitivity setting 2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment
Vibration resistance 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each
Applicable regulations CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Timer function:Timer period 0.1 to 999.9 ms approx., in units of 0.1 ms approx.
Emitting element (modulated) Red LED (Peak emission wavelength: 660 nm 0.026 mil)
Incident light sensitivity setting Incorporated, 4 steps
Communication output (C/Q):Baud rate COM3 (230.4 kbps)(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Control output (DO):Output operation Switchable either Light-ON or Dark-ON by L/D mode
Incident light intensity display range STD: 0 to 4,000, LONG: 0 to 8,000, U-LG / HYPR: 0 to 9,999
Communication output (C/Q):Process data 4 byte(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Control output (DO):Short-circuit protection Incorporated
Communication output (C/Q):Minimum cycle time 1.0 ms(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Communication output (C/Q):IO-Link communication IO-Link Specification V1.1(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Different frequency interference prevention function Incorporated (up to 4 units). Note that the response time varies depending on the setting.F-1: 0.8 ms or less, F-2: 0.9 ms or less, F-3: 1.0 ms or less, F-4: 1.7 ms or less(Note:)This function increases the hysteresis. Check the sensing condition when using the function.

Descrição do produto

FX-550L Series. Amplifier F. Optical, 1 digital output PNP, dual display, IO Link connection, 2m cable
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top