Horário de atendimento: Segunda a sexta, das 9h às 18h.
UHLG105AC5 - UHLG105AC5 HL-G105-A-C5 PANASONIC Compact Laser Displacement Sensor, Standard type, 50 mm, cable 5 m
Em estoque Produto em alta

UHLG105AC5

UHLG105AC5 HL-G105-A-C5 PANASONIC Compact Laser Displacement Sensor, Standard type, 50 mm, cable 5 m

$0.00 USD
3667 em estoque
Especificações principais
Item: Specifications
Type: Standard type
Cable: 0.1mm210-core cabtyre cable, 5 m16.404 ftlong
Remark: Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃+68 ℉, sampling rate 500 μs, average number of samples: 1024, measurement center distance, object measured is made of white ceramic and analog measurement values.
Informações do fornecedor
PANASONIC
PANASONIC
Produtos: 4316
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Item Specifications
Type Standard type
Cable 0.1mm210-core cabtyre cable, 5 m16.404 ftlong
Remark Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃+68 ℉, sampling rate 500 μs, average number of samples: 1024, measurement center distance, object measured is made of white ceramic and analog measurement values.
Weight Net weight: 70 g approx. (not including cable), 320 g approx. (including cable)Gross weight: 380 g approx.
Details Sensor head (Standard type)
Product Compact Laser Displacement Sensor
Material Enclosure: PBTFront cover: AcrylicCable: PVC
Accessory Warning label: 1 set
Linearity ± 0.1 % F.S.
Resolution 1.5 μm0.059 mil
Multi input Zero set, zero set off, reset, memory switching, teaching, saving, and laser control according to the input time.In case NPN output is selected, Function varies according to the time 0 V is connected NPN.In case PNP output is selected, Function varies according to the time external power + is connected.
Part Number HL-G105-A-C5
Light source Red semiconductor laser, Class 2 (IEC / EN / JIS / GB / KS / FDA (Note:This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.Max. output: 1 mW (Peak emission wavelength: 655 nm0.026 mil)
Product name Compact Laser Displacement Sensor HL-G1
Timing input NPN output operates when 0V is connected and NPN is set. (It depends on the setting.)PNP output operates when external power + is connected and PNP is set. (It depends on the setting.)
Beam diameter 0.5 × 0.1 mm0.020 x 0.039 in(Note) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2(13.5 %) of the center light intensity. Ifthere is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than thesensing point itself, then the results may be affected.
Sampling rate 200 μs, 500 μs, 1 ms, 2 ms
Product Number HL-G105-A-C5
Supply voltage 24 V DC ± 10 % including ripple 0.5 V (P-P)
Digital display Red LED 5 digit display
Measuring range ± 10 mm± 0.394 in
Indicator : Alarm Orange LED lights up when this product cannot measure because of insuffienct or excessive light intensity.
Receiving element CMOS image sensor
Operating altitude 2,000 m6561 ftor less
Current consumption 100 mA or less
Degree of pollution 2
Insulation resistance 20 MOhm , or more, with 250 V DC between all supply teminals connected together and enclosure
Regulatory compliance CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Analog output : Current Output range: 3.2 to 20.8 mA (normal), 21.6 mA (alarm)Load impedance: 300 Ω or less
Analog output : Voltage Output range: 0 to +10.5 V (normal), 11 V (alarm)Output impedance: 100 Ohm
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Indicator : Laser emission Green LED (lights up during laser emission)
Measurement center distance 50 mm1.969 in
Temprerature characteristics ± 0.08 % F.S. / ℃
Indicator : Measurement range Three yellow LED
Output polarity setting input NPN open collector output operates when 0 V is connected.PNP open collector output operates when 24 V DC is connected.
Outputs (OUT 1, OUT 2, OUT 3) Judgment output or alarm output (Setting can be selected.)Selectable NPN transistor open-collector or PNP transistor open-collector-Maximum sink current: 50 mA-Applied voltage: 3 to 24 V DC (between output and 0 V)-Residual voltage: 2 V or less (at 50 mA of sink current)-Maximum source current: 50 mA-Residual voltage: 2.8 V or less (at 50 mA of source current)
Environmental resistance : Protection IP67
Environmental resistance : Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Environmental resistance : Shock resistance 500 m/s2acceleration (50 G approx.) in X,Y and Z directions three times each
Environmental resistance : Ambient illuminance Incandescent light: 3,000 liter x or less at the light-receiving face(Note) The fluctuation by ambient illuminance is ± 0.1 % F.S. or less.
Environmental resistance : Ambient temperature -10 to +45 ℃+14 to +113 ℉(No dew condensation allowed), Storage: -20 to +60 ℃-4 to +140 ℉
Environmental resistance : Vibration resistance 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm0.059 indouble amplitude in X,Y and Z directions for two hours each
Output (OUT 1, OUT 2, OUT 3) : Output operation Opened when the amount of light is insufficient.
Output (OUT 1, OUT 2, OUT 3) : Short circuit protection Incorporated (automatic restoration)

Descrição do produto

CMOS class 2 measuring laser, IP67, Diffuse Reflection, built-in display and amplifier, 2 s. analog, 3 selectable digital outputs PNP/NPN, standard model, measurement range: 50 ± 10 mm., resolution:1.
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top