Horário de atendimento: Segunda a sexta, das 9h às 18h.
URDK 6 - URDK 6 3026706 PHOENIX CONTACT Feed-through terminal block
Em estoque Produto em alta

URDK 6

URDK 6 3026706 PHOENIX CONTACT Feed-through terminal block

$5.65 USD
1819 em estoque
Especificações principais
GTIN: 4017918451844
Orderkey: 3026706
Catalog page: Page 487 (C-1-2017)
Packing unit: 50 pc
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4017918451844
Orderkey 3026706
Catalog page Page 487 (C-1-2017)
Packing unit 50 pc
Width (General) 8.2 mm
Length (General) 91 mm
Country of origin PL (Poland)
(Connection data) IEC 60947-7-1
Custom tariff number 85369010
(Key Commercial Data) HL 1 - HL 3
Height NS 32 (General) 56 mm
Minimum order quantity 50 pc
Height NS 35/15 (General) 58.5 mm
Screw thread (Dimensions) M4
Height NS 35/7,5 (General) 51 mm
Color (Key Commercial Data) gray
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Stripping length (Dimensions) 10 mm
Connection method (Dimensions) Screw connection
Tightening torque max (Dimensions) 1.4 Nm
Tightening torque, min (Dimensions) 1.2 Nm
Weight per Piece (excluding packing) 27.460 g
Open side panel (Key Commercial Data) Yes
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
Internal cylindrical gage (Dimensions) A5
Number of levels (Key Commercial Data) 1
Finger protection (Key Commercial Data) guaranteed
Bending test turns (Key Commercial Data) 135
Nominal current IN (Key Commercial Data) 41 A
Nominal voltage UN (Key Commercial Data) 500 V
Degree of pollution (Key Commercial Data) 3
Insulating material (Key Commercial Data) PA
Rated surge voltage (Key Commercial Data) 6 kV
Tensile test result (Key Commercial Data) Test passed
Maximum load current (Key Commercial Data) 57 A (with 10 mm² conductor cross section)
Overvoltage category (Key Commercial Data) III
Nominal cross section (Key Commercial Data) 6 mm²
Number of connections (Key Commercial Data) 2
Temperature-rise test (Key Commercial Data) Test passed
Result of bending test (Key Commercial Data) Test passed
Conductor cross section AWG max. (Dimensions) 8
Conductor cross section AWG min. (Dimensions) 20
Tractive force setpoint (Key Commercial Data) 90 N
Conductor cross section solid max. (Dimensions) 10 mm²
Conductor cross section solid min. (Dimensions) 0.5 mm²
Insulating material group (Key Commercial Data) I
Requirements, voltage drop (Key Commercial Data) U1≤ 3.2 mV; U2≤ 1.5 x U1
Back of the hand protection (Key Commercial Data) guaranteed
Bending test rotation speed (Key Commercial Data) 10 rpm
Result of voltage-drop test (Key Commercial Data) Test passed
Surge voltage test setpoint (Key Commercial Data) 7.3 kV
Conductor cross section flexible max. (Dimensions) 6 mm²
Conductor cross section flexible min. (Dimensions) 0.5 mm²
Connection in acc. with standard (Connection data) CUL
Result of surge voltage test (Key Commercial Data) Test passed
NF F16-101, NF F10-102 Class F (Key Commercial Data) 2
NF F16-101, NF F10-102 Class I (Key Commercial Data) 2
Connection in acc. with standard (Key Commercial Data) IEC 60947-7-1
Oxygen index (DIN EN ISO 4589-2) (Key Commercial Data) >32 %
Flammability rating according to UL 94 (Connection data) V0
Shock protection test specification (Key Commercial Data) DIN EN 50274 (VDE 0660-514):2002-11
Conductor cross section tensile test (Key Commercial Data) 10 mm²
Flame test method (DIN EN 60695-11-10) (Key Commercial Data) V0
Flammability rating according to UL 94 (Key Commercial Data) V0
Smoke gas toxicity NFPA 130 (SMP 800C) (Key Commercial Data) passed
2 conductors with same cross section, solid max. (Dimensions) 2.5 mm²
2 conductors with same cross section, solid min. (Dimensions) 0.5 mm²
2 conductors with same cross section, stranded max. (Dimensions) 4 mm²
2 conductors with same cross section, stranded min. (Dimensions) 0.5 mm²
Power frequency withstand voltage setpoint (Key Commercial Data) 1.89 kV
Surface flammability NFPA 130 (ASTM E 162) (Key Commercial Data) passed
Bending test conductor cross section/weight (Key Commercial Data) 0.5 mm² / 0.3 kg
Static insulating material application in cold (Key Commercial Data) -60 °C
Behavior in fire for rail vehicles (DIN 5510-2) (Key Commercial Data) Test passed
Maximum power dissipation for nominal condition (Key Commercial Data) 1.31 W
Calorimetric heat release NFPA 130 (ASTM E 1354) (Key Commercial Data) 28 MJ/kg
Result of power-frequency withstand voltage test (Key Commercial Data) Test passed
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Connection data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Key Commercial Data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Key Commercial Data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Key Commercial Data) HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) (Key Commercial Data) passed
Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions) 6 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions) 0.5 mm²
Relative insulation material temperature index (Elec., UL 746 B) (Key Commercial Data) 130 °C
Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions) 6 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions) 0.5 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Key Commercial Data) 130 °C
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. (Dimensions) 2.5 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. (Dimensions) 0.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions) 4 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (Dimensions) 0.5 mm²
Result of the test for mechanical stability of terminal points (5 x conductor connection) (Key Commercial Data) Test passed

Descrição do produto

Feed-through terminal, nominal voltage: 500 V, nominal current: 41 A, connection type: Screw connection, 1st floor, Dimensioning cross-section: 6 mm², cross-section: 0.5 mm² - 10 mm², mounting class:
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top