Horário de atendimento: Segunda a sexta, das 9h às 18h.
UST4A1J02V - UST4A1J02V ST4-A1-J02V PANASONIC Safety, Thu-beam sensor, 15m, emission adjuster, cable 0.2m
Em estoque Produto em alta

UST4A1J02V

UST4A1J02V ST4-A1-J02V PANASONIC Safety, Thu-beam sensor, 15m, emission adjuster, cable 0.2m

$0.00 USD
3211 em estoque
Especificações principais
Item: Specifications
Cable: Shielded cable with connector, 0.2 m0.656 ftlong
Details: Sensor head
Product: Compact Type 4 Safety Beam Sensor
Informações do fornecedor
PANASONIC
PANASONIC
Produtos: 4316
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Item Specifications
Cable Shielded cable with connector, 0.2 m0.656 ftlong
Details Sensor head
Product Compact Type 4 Safety Beam Sensor
Material Enclosure: PBT (Polybutylene terephthalate)Lens: AcrylicIndicator cover: Acrylic
Part Number ST4-A1-J02V
Product name Compact Type 4 Safety Beam Sensor ST4
Power voltage Supplied from controller
Product Number ST4-A1-J02V
Sensing object φ9 mmφ0.354 inor more opaque object
Cable extension Extention up to total 50 m164.042 ftis possible for both emitter and receiver with exclusive cable.
Operating range 0.1 to 15 m0.328 to 49.213 ft(Note:The operating range is the possible setting distance between the emitter and the receiver. It can detect sensing object of less than 0.1 m 0.328 ft away.)
Emitting element Infrared LED (Peak emission wavelength: 870 nm0.034 mil)
Ambient illuminance Incandescent lamp: 3,500 Lx or less at the light-receiving face
Current consumption Emitter: 11 mA or lessReceiver: 9 mA or less
Applicable standards IEC 61496-1/2 (JIS B 9704-1/2 / UL 61496-1/2) (Type 4), ISO 13849-1:2015 (Category 4, PLe), JIS B 9705-1 (Category 4), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), JIS C 0508-1 to 3 (SIL3), UL 1998, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI/RIA R15.06, ANSI/ISA S84.01 (SIL3)(Note) Complies with those standards only when the sensor head is used in combination with the controller ST4-C11 / ST4-C12EX.
Beam emission indicator Green LED (lights up during beam emission, lights off during emission halt)
Effective aperture angle plus or minus 2.5degrees or less for operating range exceeding 3 m 9.843 ft (required by IEC 61496-2 / UL 61496-2)
Beam interruption indicator Red LED (lights up when the beam is interrupted or lock out, lights off during reception)(Note) Shows light interruption information between the emitter and the receiver with the same address. It does not show OSSD output.
Stable incident beam indicator Green LED (lights up under stable light received condition, lights off under unstable light received condition)
CE marking directive compliance Machinery Directive, EMC Directive, RoHS Directive
Weight(Total of emitter and receiver) Net weight: 45 g approx.Gross weight: 60 g approx.
Environmental resistance:Ambient humidity 30 to 85 % RH, Storage: 30 to 95 % RH
Environmental resistance:Shock resistance 300 m/s2acceleration in X, Y and Z directions three times each
Environmental resistance:Ambient temperature -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉
Environmental resistance:Degree of protection IP67 (IEC)
Environmental resistance:Vibration resistance 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 90 m/s2 in X, Y and Z directions for two hours each<
Environmental resistance:Insulation resistance 20 MOhm or more with 500V DC megger between all supply terminals connected together and enclosure
Environmental resistance:Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure

Descrição do produto

Category 4 safety barrier sensor head, independent beams, IP67, 0.1 to 15m, built-in 0.2m cable, sensitivity adjustment
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top