Especificações principais
: 500 A
Color: gray (RAL 7042)
Depth: 56.5 mm
Pitch: 8.2 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
500 A
Color gray (RAL 7042)
Depth 56.5 mm
Pitch 8.2 mm
Width 114.8 mm
Height 81 mm
Result Test passed
Spectrum Service life test category 2, bogie-mounted
ASD level 6.12 (m/s²)²/Hz
Frequency f1= 5 Hz to f2= 250 Hz
Potentials 10
Pulse shape Half-sine
Revolutions 135
Acceleration 3.12g
Product type Test terminal strip
Screw thread M4
Mounting type Wall mounting
Specification DIN EN 50155 (VDE 0115-200):2008-03
Number of rows 1
Rotation speed 10 rpm
Shock duration 18 ms
Nominal voltage 400 V AC/DC
Open side panel No
Plate thickness 1 mm ... 4 mm
Test directions X-, Y- and Z-axis
Stripping length 12 mm
Time of exposure 30 s
Cross section AWG 24 ... 8 (converted acc. to IEC)
Tightening torque 1.5 ... 1.8 Nm
Temperature cycles 192
Test surge voltage 5 kV
Dimensional drawing
Insulating material PA
Number of positions 10
Rated surge voltage 4 kV
Test force setpoint 5 N
Maximum load current 30 A (with 10 mm² conductor cross section)
Overvoltage category III
Nominal cross section 6 mm²
Number of connections 20
Test voltage setpoint 4.8 kV
Test duration per axis 5 h
Terminal block mounting 0.8 Nm ... 1 Nm
Insulating material group I
Internal cylindrical gage A5
Conductor cross section rigid 0.2 mm² ... 10 mm²
Ambient temperature (assembly) -5 °C ... 70 °C
Conductor cross section/weight 0.2 mm² / 0.2 kg
Number of shocks per direction 3
Ambient temperature (actuation) -5 °C ... 70 °C
Number of connections per level 20
Conductor cross section flexible 0.2 mm² ... 10 mm²
Connection in acc. with standard IEC 60947-7-1
Requirement temperature-rise test Increase in temperature ≤ 45 K
Short-time withstand current 4 mm² 300 A
Flammability rating according to UL 94 V0
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG] 24 ... 8 (converted acc. to IEC)
Permissible humidity (storage/transport) 30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162) passed
2 conductors with same cross section, solid 0.2 mm² ... 2.5 mm²
2 conductors with same cross section, flexible 0.2 mm² ... 2.5 mm²
Static insulating material application in cold -60 °C
Maximum power dissipation for nominal condition 1.31 W
Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Flexible conductor cross section (ferrule with plastic sleeve) 0.25 mm² ... 6 mm²
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Conductor cross-section flexible (ferrule without plastic sleeve) 0.25 mm² ... 6 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
2 conductors with same cross section, flexible, with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 0.5 mm² ... 2.5 mm²

Descrição do produto

Test pin strip, rated voltage: 400 V, number of connections: 20, number of poles: 10, connection type: Screw connection, 1st floor, Sizing section: 6 mm², cross-section: 0.2 mm² - 10 mm², mounting cla