Horário de atendimento: Segunda a sexta, das 9h às 18h.
VAL-MS 400/3+0/VF-FM - VAL-MS 400/3+0/VF-FM 2910476 PHOENIX CONTACT Type 2 surge protection device
Em estoque Produto em alta

VAL-MS 400/3+0/VF-FM

VAL-MS 400/3+0/VF-FM 2910476 PHOENIX CONTACT Type 2 surge protection device

$0.00 USD
3792 em estoque
Especificações principais
GTIN: 4055626459172
Note: Made to Order (non-returnable)
Orderkey: 2910476
(General): At altitudes > 2000 m (amsl), a lateral distance of 2 mm must be maintained between live and grounded parts.
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4055626459172
Note Made to Order (non-returnable)
Orderkey 2910476
(General) At altitudes > 2000 m (amsl), a lateral distance of 2 mm must be maintained between live and grounded parts.
Packing unit 1 pc
Country of origin DE (Germany)
(Connection data) EN 61643-11 2012
Custom tariff number 85363010
(Ambient conditions) PBT
(Protective circuit) 1 A DC
Altitude (Dimensions) ≤ 5000 m (amsl (above mean sea level))
Type (Ambient conditions) DIN rail module, two-section, divisible
Color (Ambient conditions) jet black RAL 9005
Depth (Key Commercial Data) 65.7 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data) 71 mm
EN type (Ambient conditions) T2
Height (Key Commercial Data) 98.7 mm
(Indicator/remote signaling) 4.5 Nm (25 mm² ... 35 mm²)
Shock (operation) (Dimensions) 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Degree of protection (Dimensions) IP20 (only when all terminal points are used)
Screw thread (Protective circuit) M2
Mounting type (Ambient conditions) DIN rail: 35 mm
Vibration (operation) (Dimensions) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Weight per Piece (excluding packing) 393.500 g
Housing material (Ambient conditions) PA 6.6
Stripping length (Protective circuit) 7 mm
Connection method (Protective circuit) Plug-in/screw connection via COMBICON
Horizontal pitch (Key Commercial Data) 4 Div.
Operating current (Protective circuit) 5 mA AC ... 750 mA AC
Operating voltage (Protective circuit) 5 V AC ... 250 V AC (Altitude ≤ 2000 m amsl)
Tightening torque (Protective circuit) 0.25 Nm
Mode of protection (Ambient conditions) L-PE
Standards/regulations (Connection data) IEC 61643-11 2011
Switching function (Protective circuit) PDT contact
Degree of pollution (Ambient conditions) 2
Number of positions (Ambient conditions) 4
Screw thread (Indicator/remote signaling) M5
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
IEC test classification (Ambient conditions) II
Nominal voltage UN (Additional descriptions) 400 V AC (IT)
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Stripping length (Indicator/remote signaling) 16 mm
Connection method (Indicator/remote signaling) Fork-type cable lug
Nominal frequency fN (Additional descriptions) 50 Hz (60 Hz)
Residual current IPE (Additional descriptions) ≤ 5 µA
Tightening torque (Indicator/remote signaling) 3 Nm (1,5 mm² ... 16 mm²)
Rated load current IL (Additional descriptions) 80 A
Response time tA(L-L) (Additional descriptions) ≤ 25 ns
Conductor cross section AWG (Protective circuit) 28 ... 16
Response time tA(L-PE) (Additional descriptions) ≤ 100 ns
Conductor cross section solid (Protective circuit) 0.14 mm² ... 1.5 mm²
Surge protection fault message (Ambient conditions) Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Residual voltage Ures(L-L) (Additional descriptions) ≤ 4 kV (at In)
Conductor cross section flexible (Protective circuit) 0.14 mm² ... 1.5 mm²
Residual voltage Ures(L-PE) (Additional descriptions) ≤ 2.3 kV (at In)
Standby power consumption PC (Additional descriptions) ≤ 600 mVA
Maximum continuous voltage UC (Additional descriptions) 440 V AC
Conductor cross section AWG (Indicator/remote signaling) 15 ... 2
Conductor cross section solid (Indicator/remote signaling) 1.5 mm² ... 35 mm²
Voltage protection level Up(L-L) (Additional descriptions) ≤ 4 kV
Flammability rating according to UL 94 (Ambient conditions) V-0
Voltage protection level Up(L-PE) (Additional descriptions) ≤ 3.5 kV
Short-circuit current rating ISCCR (Additional descriptions) 25 kA
Conductor cross section flexible (Indicator/remote signaling) 1.5 mm² ... 16 mm²
Max. backup fuse with branch wiring (Additional descriptions) 100 A (gG)
Nominal discharge current In(8/20) µs (Additional descriptions) 20 kA
Maximum discharge current Imax(8/20) µs (Additional descriptions) 40 kA
Max. backup fuse with V-type through wiring (Additional descriptions) 80 A (gG)

Descrição do produto

3-channel surge protection device, for mounting on NS 35/7.5, with remote indication (FM) contact as switch, 400 V AC voltage
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top