Horário de atendimento: Segunda a sexta, das 9h às 18h.
VAL-US 60/1+1/1U/FM - VAL-US 60/1+1/1U/FM 2909630 PHOENIX CONTACT Type 2 surge arrester
Em estoque Produto em alta

VAL-US 60/1+1/1U/FM

VAL-US 60/1+1/1U/FM 2909630 PHOENIX CONTACT Type 2 surge arrester

$0.00 USD
3943 em estoque
Especificações principais
GTIN: 4055626370538
Note: Made to Order (non-returnable)
Orderkey: 2909630
Packing unit: 1 pc
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4055626370538
Note Made to Order (non-returnable)
Orderkey 2909630
Packing unit 1 pc
Country of origin US (United States)
(Connection data) (L-) - G
Custom tariff number 85363010
(Ambient conditions) PBT
(Protective circuit) 1 A (30 V DC)
(UL connection data) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Altitude (Dimensions) ≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions) DIN rail module, two-section, divisible
(Additional descriptions) ≤ 0.275 kV (at 3 kA)
Color (Ambient conditions) gray
SPD Type (Connection data) 4CA
Depth (Key Commercial Data) 85.6 mm
Width (Key Commercial Data) 70.6 mm
EN type (Ambient conditions) T2
Height (Key Commercial Data) 40.6 mm
(Indicator/remote signaling) 10 ... 2 (UL)
Shock (operation) (Dimensions) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
China RoHS (UL connection data) Environmentally Friendly Use Period = 50
Degree of protection (Dimensions) IP20 (only when all terminal points are used)
Height unit (Key Commercial Data) 1 U
Nominal voltage (Connection data) 60 V DC
Mounting type (Ambient conditions) Panel mount
Vibration (operation) (Dimensions) 7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Mode of protection (Connection data) N-G
Weight per Piece (excluding packing) 222.220 g
Housing material (Ambient conditions) PA 6.6
Operating current (UL specifications) 1 A AC
Operating voltage (UL specifications) 125 V AC
Stripping length (Protective circuit) 6 mm
Connection method (Protective circuit) Push-in spring connection
Operating current (Protective circuit) 5 mA AC ... 1.5 A
Operating voltage (Protective circuit) 5 V AC ... 250 V AC
Mode of protection (Ambient conditions) L-N
Switching function (Protective circuit) PDT contact
Degree of pollution (Ambient conditions) 2
Screw thread (Indicator/remote signaling) M5
Response time tA (Additional descriptions) ≤ 25 ns
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
IEC power supply system (Ambient conditions) TN-S
IEC test classification (Ambient conditions) II
Nominal voltage UN (Additional descriptions) -48 V DC ±10 % (RRH)
TOV behavior at UT (Additional descriptions) 100 V AC (5 s / withstand mode)
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Stripping length (Indicator/remote signaling) 16 mm
Connection method (Indicator/remote signaling) Screw connection
Nominal frequency fN (Additional descriptions) 50 Hz (60 Hz)
Residual current IPE (Additional descriptions) ≤ 0.45 mA
Tightening torque (Indicator/remote signaling) 2.5 Nm ... 3 Nm
Conductor cross section AWG (UL specifications) 30 ... 14
Rated load current IL (Additional descriptions) 80 A
Residual voltage Ures (Additional descriptions) ≤ 0.55 kV (at In)
Conductor cross section AWG (Protective circuit) 24 ... 20 (UL)
Tightening torque (UL indicator/remote signaling) 22 lbf-in. ... 26.5 lbf-in.
Surge protection fault message (Ambient conditions) Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Voltage protection level Up (Additional descriptions) ≤ 0.55 kV
Standby power consumption PC (Additional descriptions) ≤ 35 mVA
Conductor cross section solid max. (Protective circuit) 0.5 mm²
Conductor cross section solid min. (Protective circuit) 0.14 mm²
Maximum continuous voltage UC (Additional descriptions) 75 V AC
Conductor cross section AWG (Indicator/remote signaling) 15 ... 2
Conductor cross section flexible max. (Protective circuit) 0.5 mm²
Conductor cross section flexible min. (Protective circuit) 0.2 mm²
Conductor cross section AWG (UL indicator/remote signaling) 10 ... 2
Flammability rating according to UL 94 (Ambient conditions) V-0
Short-circuit current rating ISCCR (Additional descriptions) 25 kA
Max. backup fuse with branch wiring (Additional descriptions) 160 A AC (gG)
Conductor cross section solid max. (Indicator/remote signaling) 35 mm²
Conductor cross section solid min. (Indicator/remote signaling) 1.5 mm²
Nominal discharge current In(8/20) µs (Additional descriptions) 15 kA
Maximum continuous operating voltage MCOV (L-N) (Connection data) 75 V AC
Conductor cross section flexible max. (Indicator/remote signaling) 25 mm²
Conductor cross section flexible min. (Indicator/remote signaling) 1.5 mm²
Maximum discharge current Imax(8/20) µs (Additional descriptions) 40 kA
Max. backup fuse with V-type through wiring (Additional descriptions) 80 A AC (gG - 16 mm²)

Descrição do produto

Universal plug-in surge and lightning current protection device equipped with varistors for 48–60 V DC applications with two conductors and grounding, with remote indication contact
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top